详情
BUY HD74LS148P https://www.utsource.net/itm/p/117189.html
Encoder
| Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
| Operating Supply Voltage |
VCC |
Continuous operation |
4.75 |
- |
5.25 |
V |
| Input High Level Voltage |
VIH |
II = -0.4 mA |
2.0 |
- |
VCC |
V |
| Input Low Level Voltage |
VIL |
II = -1.6 mA |
0 |
- |
0.8 |
V |
| Output High Level Voltage |
VOH |
IO = -0.4 mA |
2.4 |
- |
VCC - 0.5 |
V |
| Output Low Level Voltage |
VOL |
IO = 16 mA |
0 |
- |
0.5 |
V |
| Propagation Delay Time |
tpd |
VCC = 5V, TA = 25°C |
- |
22 |
34 |
ns |
| Power Dissipation |
PD |
Continuous operation |
- |
- |
100 |
mW |
| Operating Temperature Range |
TA |
Continuous operation |
-55 |
- |
125 |
°C |
Instructions for Using HD74LS148P
Power Supply:
- Connect the VCC pin to a 5V supply.
- Ground the GND pin.
Input Connections:
- Connect the inputs (I0 to I7) to either VCC (high) or GND (low) based on your logic requirements.
- Ensure that all unused inputs are tied to a known state (either high or low) to avoid floating conditions.
Output Connections:
- The outputs (Y0 to Y2) will provide the binary code corresponding to the active input.
- The active-low output (G*) indicates when one of the inputs is active (low).
Enable and Inhibit:
- Use the enable input (E*) to control the operation of the encoder. When E* is low, the encoder is enabled. When E* is high, all outputs are high (inactive).
- The inhibit input (I*) can be used to disable the encoder. When I* is low, the encoder operates normally. When I* is high, all outputs are high (inactive).
Propagation Delay:
- The propagation delay time (tpd) is the time it takes for a change in the input to affect the output. Ensure that your system timing accounts for this delay.
Temperature Considerations:
- The device is designed to operate within the temperature range of -55°C to 125°C. Ensure that the operating environment does not exceed these limits to maintain reliable performance.
Power Dissipation:
- The maximum power dissipation is 100 mW. Ensure adequate heat dissipation if the device is expected to operate near its maximum power rating.
Handling Precautions:
- Handle the device with care to avoid damage from electrostatic discharge (ESD). Use proper ESD protection measures during handling and installation.
By following these instructions, you can ensure the proper operation and longevity of the HD74LS148P priority encoder.