| 
			 Model No.  | 
			
			 PTH-80A  | 
			
			 PTH-150A  | 
			
			 PTH-225A  | 
			
			 PTH-416A  | 
			
			 PTH-800A  | 
			
			 PTH-1000A  | 
			
			 PTH-80A  | 
			
			 PTH-150B  | 
			
			 PTH-225B  | 
			
			 PTH-416B  | 
			
			 PTH-800B  | 
			
			 PTH-1000B  | 
		|||
| 
			 Internal Dimensions  | 
			
			 W  | 
			
			 400  | 
			
			 500  | 
			
			 500  | 
			
			 700  | 
			
			 1000  | 
			
			 1000  | 
			
			 400  | 
			
			 500  | 
			
			 500  | 
			
			 700  | 
			
			 1000  | 
			
			 1000  | 
		||
| 
			 
  | 
			
			 H  | 
			
			 500  | 
			
			 600  | 
			
			 750  | 
			
			 850  | 
			
			 1000  | 
			
			 1000  | 
			
			 500  | 
			
			 600  | 
			
			 750  | 
			
			 850  | 
			
			 1000  | 
			
			 1000  | 
		||
| 
			 
  | 
			
			 D  | 
			
			 400  | 
			
			 500  | 
			
			 600  | 
			
			 700  | 
			
			 800  | 
			
			 1000  | 
			
			 400  | 
			
			 500  | 
			
			 600  | 
			
			 700  | 
			
			 800  | 
			
			 1000  | 
		||
| 
			 External Dimensions (mm)  | 
			
			 W  | 
			
			 930  | 
			
			 1030  | 
			
			 1080  | 
			
			 1230  | 
			
			 1530  | 
			
			 1530  | 
			
			 930  | 
			
			 1030  | 
			
			 1080  | 
			
			 1230  | 
			
			 1530  | 
			
			 1530  | 
		||
| 
			 
  | 
			
			 H  | 
			
			 1310  | 
			
			 1410  | 
			
			 1620  | 
			
			 1660  | 
			
			 1810  | 
			
			 1810  | 
			
			 1310  | 
			
			 1410  | 
			
			 1620  | 
			
			 1660  | 
			
			 1810  | 
			
			 1810  | 
		||
| 
			 
  | 
			
			 D  | 
			
			 810  | 
			
			 910  | 
			
			 1120  | 
			
			 1210  | 
			
			 1310  | 
			
			 1510  | 
			
			 810  | 
			
			 910  | 
			
			 1120  | 
			
			 1210  | 
			
			 1310  | 
			
			 1510  | 
		||
| 
			 Volume (L)  | 
			
			 80  | 
			
			 150  | 
			
			 225  | 
			
			 416  | 
			
			 800  | 
			
			 1000  | 
			
			 80  | 
			
			 150  | 
			
			 225  | 
			
			 416  | 
			
			 800  | 
			
			 1000  | 
		|||
| 
			 Temperature Range  | 
			
			 0℃~100℃(150℃)  | 
			
			 -20℃~100℃(150℃)  | 
		|||||||||||||
| 
			 The Evenness Of Humiture Distribu tion  | 
			
			 ±0.5℃ ±3%RH  | 
			
			 ± 1 ℃ ± 5 %R H  | 
			
			 ±0.5℃ ±3%RH  | 
			
			 ± 1 ℃ ± 5 %R H  | 
		|||||||||||
| 
			 Temperature Rising Speed  | 
			
			 0℃~100℃ about 20min  | 
			
			 -20℃~100℃ about 35min  | 
		|||||||||||||
| 
			 Temperature Falling Speed  | 
			
			 20℃~0℃ about 20min  | 
			
			 20℃~20℃ about 45min  | 
		|||||||||||||
| 
			 Freezing System  | 
			
			 1PC of fully sealed air cooling system  | 
		||||||||||||||
| 
			 Humidity Range  | 
			
			 20%~98%RH  | 
		||||||||||||||
| 
			 Humiture Stability  | 
			
			 ±0.2℃ ±2%RH  | 
		||||||||||||||
| 
			 Humiture Adjustment  | 
			
			 Auto balancing temperature and humidity adjustment  | 
		||||||||||||||
| 
			 Outside Materials  | 
			
			 Stainless steel sus # 304  | 
		||||||||||||||
| 
			 Inside Materials  | 
			
			 Stainless steel sus # 304  | 
		||||||||||||||
| 
			 Humidifying System  | 
			
			 Surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device.  | 
		||||||||||||||
| 
			 Thermal Material  | 
			
			 Heat preserved by rock wool and hardened pu foaming  | 
		||||||||||||||
| 
			 Heating System  | 
			
			 Heater with stainless steel dissipation  | 
		||||||||||||||
| 
			 Circulatory Syste m  | 
			
			 Convection by fan forced circulatory system  | 
		||||||||||||||
| 
			 Dehumidifying System  | 
			
			 Freezing dehumidifying system  | 
		||||||||||||||
| 
			 Water Supplying System  | 
			
			 The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water.  | 
		||||||||||||||
| 
			 Safety Devices  | 
			
			 Leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, overtemperatureprotection device for humidifier and the protection device for limit of temperature.  | 
		||||||||||||||
| 
			 Standard Delivery  | 
			
			 Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator.  | 
		||||||||||||||
| 
			 Optional Accessories  | 
			
			 Recorder  | 
		||||||||||||||
| 
			 Power  | 
			
			 AC220V/50, AC110V/60HZ  | 
		||||||||||||||
更多 LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 相关资料