Model: RG-S2910-24GT4XS-E
RUIJIE RG-S2910XS 24-PORT GIGABIT L2+ MANAGED SWITCH WITH SFP+
Ruijie RG-S2910XS-E/P is a collection of next-gen Gigabit switches architected for superior security, switch delivers Non-blocking / wire-speed,high performance and outstanding energy efficiency. The series delivers full Gigabit access and unparalleled scalability to 10G performance. With the all-new hardware architecture and Ruijie’s latest RGOS11.X modular operating system, the RG-S2910XS-E/P switches offer larger table capacity, faster hardware processing performance and a better operation experience than anything previous. In addition, the PoE models in various specifications support all downlink ports running on PoE+ and fulfill high bandwidth demand of 10G uplink. The RG-S2910XS-E/P switches guarantee high-density user access and leading aggregation performance with ease.
KEY FEATURES
| odel | RG-S2910-24GT4XS-E | RG-S2910-48GT4XS-E | RG-S2910-10GT2SFP-P-E | RG-S2910C-24GT2XS-HP-E | RG-S2910C-48GT2XS-HP-E | 
| Ports | 
					24 10/100/1000BASE-T ports | 
					48 10/100/1000BASE-T ports | 10 10/100/1000BASE-T ports 2 100/1000BASE-X SFP ports (non-combo) | 
					24 10/100/1000BASE-T ports (PoE/PoE+) | 
					48 10/100/1000BASE-T ports (PoE/PoE+) | 
| Expansion Slots | N/A | N/A | N/A | 2 | 2 | 
| Modular Power Slots | N/A | N/A | N/A | 2 | 2 | 
| Fan Slots | Fixed | Fixed | Fanless | Fixed | Fixed | 
| Expansion Modules | N/A | N/A | N/A | 
					M2910-01XS | 
					M2910-01XS | 
| Management Ports | 1 console port | 1 console port | 1 console port | 
					1 console port | 
					1 console port | 
| Switching Capacity | 264Gbps | 264Gbps | 256Gbps | 264Gbps | 264Gbps | 
| Packet Forwarding Rate | 96Mpps | 132Mpps | 18Mpps | 96Mpps | 132Mpps | 
| Max. Number of 10GE Ports | 4 | 4 | N/A | 4 | 4 | 
| PoE | N/A | N/A | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking | IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking | 
| Port Buffer | 1.5MB | ||||
| RAM | 512MB | ||||
| ARP Table | 1,000 | 1,000 | 500 | 1,000 | 1,000 | 
| MAC Address | 16K | ||||
| 
					Routing Table Size | 500 (IPv4/IPv6) | 500 (IPv4/IPv6) | 64 (IPv4/IPv6) | 500 (IPv4/IPv6) | 500 (IPv4/IPv6) | 
| ACL Entries | 
					In: 1,500 | 
					In: 1,500 | In: 750 Out: N/A | 
					In: 1,500 | 
					In: 1,500 | 
| VLAN | 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN | ||||
| QinQ | Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching | ||||
| Link Aggregation | AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance | ||||
| Port Mirroring | Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN # RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring | ||||
| Spanning Tree Protocols | IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG) | ||||
| DHCP | DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82 | ||||
| Multiple Spanning Tree Protocol (MSTP) Instances | 64 | ||||
| Maximum Aggregation Port (AP) | 128 | ||||
| SDN | OpenFlow 1.0 & 1.3 | ||||
| VSU (Virtual Switch Unit) | Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports # All models support the features above except RG-S2910-10GT2SFP-P-E | ||||
| Zero Configuration | CWMP(TR069) | ||||
| L2 Features | MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel | ||||
| Layer 2 Protocols | IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s | ||||
| IPv4 Features | Ping, Traceroute | ||||
| IPv6 Features | ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address | ||||
| IPv4 Routing Protocols | Static Routing, RIP, OSPF v1/v2 | ||||
| Basic IPv6 Protocols | IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert | ||||
| IPv6 Routing Protocols | Static routing, RIPng, OSPF v3 | ||||
| G.8032 | Support | ||||
| ACL | Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL | ||||
| QoS | 802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS | ||||
| Reliability | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module | 
| EEE Format | Support IEEE 802.3az standard | ||||
| Security | Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI) | ||||
| Manageability | SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS # RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web 
 | ||||
| Hot Patch | Support | ||||
| Smart Temperature Control | Auto fan speed adjustment; Fan malfunction alerts; Fan status check # All models support the features above except RG-S2910-10GT2SFP-P-E 
 | ||||
| Smart Power Supply | N/A | N/A | N/A | Support power control and management | Support power control and management | 
| Other Protocols | FTP, TFTP, DNS client, DNS static | ||||
| 
					Dimensions | 440 × 260 × 43.6 | 440 × 260 × 43.6 | 340 × 260 × 44 | 440 × 320 × 44 | 440 × 360 × 44 | 
| Rack Height | 1RU | ||||
| Weight | ≤3.5kg | ≤4kg | <2.5kg | 5.8kg (gross weight) | 6.8kg (gross weight) | 
| MTBF (hours) | >200K | ||||
| Lightning Protection on Power Port | Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 6KV/Differential Mode 6KV | Common Mode 4KV/Differential Mode 2K | Common Mode 4KV/Differential Mode 2K | 
| Lightening Protection on Communication Port | Common Mode 6KV | ||||
| Power Supply | 
					AC input: | 
					AC input: | AC input: Rated voltage range: 100V to 240V AC Maximum voltage range: 90V to 264V AC Frequency: 50/60Hz Rated current: 2A 
 
					HVDC input: | 
					AC power (RG-M5000E-AC500P): | 
					AC power (RG-M5000E-AC500P): | 
| Power Consumption | 24W | 50W | 165W (with 8-port PoE or 4-port PoE+) | 850W (with 24-port PoE+) | 1700W (with 48-port PoE+) | 
| PoE Power | N/A | N/A | 125W | 
					RG-M5000E-AC500P: 370W | 
					RG-M5000E-AC500P: 370W | 
| Safety Standards | IEC 60950-1, EN 60950-1 | ||||
| Emission Standards | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 | ||||
| Temperature | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 45°C | Operating temperature: 0°C to 50°C | Operating temperature: 0°C to 50°C | 
| Storage temperature: -40°C to 70°C | |||||
| Humidity | Operating humidity: 10% to 90%RH | ||||
| Storage humidity: 5% to 95%RH | |||||
| Operating Altitude | -500m to 5,000m | ||||