| Item | Data |  |  | 
		
			|  |  |  |  | 
		
			| Test standard | IEC60947-7-4/   UL1059 |  |  | 
		
			| Pitch                                              [mm] | 5 |  |  | 
		
			| Poles | 01-24P |  |  | 
		
			| IEC60947-7-4 Test data | / |  |  | 
		
			| Rated voltage                                       [V] | 400 |  |  | 
		
			| Rated current                                       [A] | 24 |  |  | 
		
			| Rated connection capacity)(solid/stranded)            [mm²] | 0.2~4.0(Sol)/0.2~2.5(Str) |  |  | 
		
			| Surge voltage category/pollution degree/material group | III/2/I |  |  | 
		
			| Rated impulse voltage                               [KV] | 4 |  |  | 
		
			| Rated torque                                      [N·m] | / |  |  | 
		
			| UL1059Test data | UL   File Number E228872 |  |  | 
		
			| Use group | B | C | D | 
		
			| Rated voltage                                       [V] | 300 | / | 300 | 
		
			| Rated   current                                       [A] | 20 | / | 10 | 
		
			| Rated connection capacity) (solid/stranded)           [AWG] | 24-Dec |  |  | 
		
			| Rated torque                                      [Lb. in] | / |  |  | 
		
			| General data | / |  |  | 
		
			| Screw | / |  |  | 
		
			| Inflammability class                                UL94 | V-0 |  |  | 
		
			| Ambient temperature                               [℃] | -40~+105 |  |  | 
		
			| Relative humidity | 5%-95% |  |  | 
		
			| Inspection standard | MIL-STD-105E   II |  |  | 
		
			| AQL | 0.65 |  |  | 
		
			| Warranty | 12   months |  |  | 
		
			| Material and plating | / |  |  | 
		
			| Housing | PA66 |  |  | 
		
			| Spring | Stainless |  |  | 
		
			| Pin header | Copper,Sn plated |  |  | 
		
			| Wire connecting |  |  |  | 
		
			| Recommended stripping length 10mm ; |  |  |  | 
		
			| 1.)For solid wire,  stripping wire to the appointed length ,put the wire into the hole after using the accessory depress the cage spring . | 
		
			| 2.)For stranded wire: stripping wire to the appointed length, can be directly connected or use of the corresponding standard insulated ferrule , then put the wire into the hole after using the accessory press the cage spring |