| Item | Data |  |  | 
		
			| APPROVAL |  |  |  | 
		
			| Test standard | IEC/EN60998-1:2004 / UL1059 |  |  | 
		
			| Pitch                                    [mm] | 5 |  |  | 
		
			| Poles | 02-XXP |  |  | 
		
			| EN60998  Test   data | 40024856 |  |  | 
		
			| Rated voltage                            [V] | 250 |  |  | 
		
			| Rated current)                              [A] | 18 |  |  | 
		
			| Rated connection capacity)(solid/stranded) [mm2] | 0.5-2.5 |  |  | 
		
			| Surge voltage category/pollution degree/material group) | III/2/I |  |  | 
		
			| Withstanding Voltage                  [KV/min] | 2 |  |  | 
		
			| Rated torque                              [N.m] | 0.34~0.40 |  |  | 
		
			| UL1059Test data | UL   File Number E228872 |  |  | 
		
			| Use group | B | C | D | 
		
			| Rated voltage                             [V] | 300 | / | / | 
		
			| Rated current                             [A] | 10 | / | / | 
		
			| Rated connection capacity (solid/stranded) [AWG] | 26~14 |  |  | 
		
			| Rated torque                           [Lb. in] | 3.01~3.54 |  |  | 
		
			| General data | / |  |  | 
		
			| Screw | M2.6 |  |  | 
		
			| Inflammability classUL94 | V-0 |  |  | 
		
			| Ambient temperature                      [℃] | -40~+105 |  |  | 
		
			| Relative humidity | 5%-95% |  |  | 
		
			| Inspection standard | MIL-STD-105E   II |  |  | 
		
			| AQL | 0.65 |  |  | 
		
			| Warranty | 12   months |  |  | 
		
			| Material and plating | / |  |  | 
		
			| Housing | PA66 |  |  | 
		
			| Screws | Steel,Zn plated |  |  | 
		
			| Contact | Copper   alloy,Sn Plated |  |  | 
		
			| Wire protector | Stainless   steel |  |  | 
		
			| Wire connecting |  |  |  | 
		
			| 5-6mm; Recommended stripping length 5-6mm; |  |  |  | 
		
			| 1.)For solid wire, stripping wire to the   appointed length, then tightening with rated torque. |  |  | 
		
			| 2.)For stranded wire: stripping wire to the appointed length,   mating with corresponding type of ferrule, then tightening with rated torque. | 
		
			| Tightening process should be steady, can’t   use explosive force. |  |  |