The Reliable, Repeatable, Accurate Way to Check Bearings and Overall Vibration
Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration and bearing condition.
What Makes the 805 the Best Choice?
Other useful features:
| Vibration Meter | ||
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz | |
| Severity levels | Good, satisfactory, unsatisfactory, unacceptable | |
| Vibration limit | 50 g peak (100 g peak-peak) | |
| A/D converter | 16-bit | |
| Signal to noise ratio | 80 dB | |
| Sampling rate | Low frequency | 20,000 Hz |
| High frequency | 80,000 Hz | |
| Real time clock backup | Coin battery | |
| Sensor | ||
| Sensitivity | 100 mV g ±10% | |
| Measurement range | 0.01 g to 50 g | |
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
| High frequency range | 4,000 Hz to 20,000 Hz | |
| Resolution | 0.01 g | |
| Accuracy | At 100 Hz ±5% of measured value | |
| Amplitude Units | ||
| Acceleration | g, m/sec² | |
| Velocity | in/sec, mm/sec | |
| Displacement | mils, mm | |
| Infrared Thermometer (Temperature Measurement) | ||
| Range | -20°C to 200°C (-4°F to 392°F) | |
| Accuracy | ±2°C (4°F) | |
| Focal length | Fixed, at ~3.8 cm (1.5 in) | |
| External sensor | ||
| Fluke supports but does not provide external sensors | ||
| Frequency range | 10 Hz to 1,000 Hz | |
| Bias voltage (to supply power) | 20 VDC to 22 VDC | |
| Bias current (to supply power) | Maximum 5 mA | |
| Firmware | ||
| External interfaces | USB 2.0 (full speed) communication | |
| Data capacity | Database on internal flash memory | |
| Upgrade | Through USB | |
| Memory | Up to 3,500 measurements | |
| Radiated Emission | ||
| Electrostatic discharge: burst | Standard EN 61000-4-2 | |
| Electromagnetic interference | Standard EN 61000-4-3 | |
| RE | Standard CISPR 11, Class A | |
| Environmental | ||
| Operating temperature | -20°C to 50°C (-4°F to 122°F) | |
| Storage temperature | -30°C to 80°C (-22°F to 176°F) | |
| Operating humidity | 10% to 95% RH (non-condensing) | |
| Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) | |
| IP rating | IP54 | |
| Vibration limit | 500 g peak | |
| Drop test | 1 meter | |
| General Specifications | ||
| Battery type | AA (2) Lithium Iron Disulfide | |
| Battery life | 250 measurements | |
| Size (L x W x H) | 24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in) | |
| Weight | 0.40 kg (0.89 lb) | |
| Connectors | USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector) | |