The Festo MPA-CPI-VI is a highly expandable and modular valve terminal featuring high-performance valves in a sturdy metal housing with metal linking . The internal communication system uses serial linking (CPI) and communicates with the higher-level controller via a CPX fieldbus connection, supporting up to 128 pneumatic valves per terminal . With the ability to combine two valve sizes (10 mm and 20 mm) on one terminal and ATEX Zone 2 certification for potentially explosive gas atmospheres, the MPA-CPI-VI delivers exceptional scalability and reliability for demanding industrial automation applications.

Key Features & Advantages

Technical Specifications

Brand: Festo

Model: MPA-CPI-VI

Product No.: 546280

Product Type: Valve Terminal / Pneumatic Valve Manifold

Type Code: MPA-CPI-VI

Terminal Type: 32

Valve Sizes Supported: 10 mm, 14 mm, 20 mm

Max. Number of Valve Positions: 32

Max. Number of Pressure Zones: 9

Max. Number of Pneumatic Valves (with serial linking): 128

Standard Nominal Flow Rate: 360 l/min (10 mm), 550 l/min (14 mm), 700 l/min (20 mm) 

Operating Pressure: -0.9 bar to 10 bar

Vacuum Suitability: Yes

Operating Medium: Compressed air to ISO 8573-1:2010 [7:4:4]

Media Note: Operation with oil lubrication possible (required for further use thereafter); when used non-lubricated, the valve is maintenance-free 

Corrosion Resistance Class (CRC): 0 – No corrosion stress 

Degree of Protection: IP65 / IP67 

Ambient Temperature: -5°C to 50°C

Media Temperature: -5°C to 50°C

Storage Temperature: -20°C to 40°C

Relative Air Humidity: Max. 90% at 40°C

ATEX Certification Gas: II 3G

Ignition Protection Type Gas: Ex nA IIC T4 X Gc (or Ex ec IIC T4 Gc X with input module CPX-P-8DE-N-IS) 

Explosive Ambient Temperature Range: -5°C ≤ Ta ≤ +50°C

ATEX Special Identification (with CPX-P-8DE-N-IS module): II 3(1)G Ex ec [ia Ga] IIC T4 Gc X / II(1)D [Ex ia IIIC Da] X 

US Hazardous Area Certification: NEC 500 Class I, Div. 2 (refer to Festo documentation)

Pilot Pressure: 3 bar to 8 bar (max. 10 bar from datasheet variations) 

Pilot Air Supply: Internal or External

Nominal Operating Voltage DC: 24 V

Permissible Voltage Fluctuation: ±25%

Protection Class: III (PELV) according to EN 61140

Pollution Degree: Min. 2 according to IEC 60664-1

Max. Switching Frequency: 10 Hz

Max. Duty Cycle at >2 Hz: 50%

Maximum Pick-up Time: Not specified

Signal Status Display: LED per coil

Valve Functions Available: 2/2 NC monostable, 2x3/2 NC monostable, 2x3/2 NO monostable, 2x3/2 open/closed monostable, 3/2 NC monostable, 3/2 NO monostable, 5/2 monostable, 5/2 bistable, 5/3 pressurised, 5/3 exhausted, 5/3 closed 

Valve Design: Piston gate valve, Poppet valve with return spring

Sealing Principle: Soft

Reset Method: Mechanical spring

Type of Control: Electric

Electrical Actuation: Fieldbus (CPI via CPX)

Electrical I/O System: No

Pneumatic Working Port Options: M7, G1/8, QS-3/16, QS-4, QS-6, QS-8, QS-1/4, QS-5/16 

Pneumatic Connection Port 1: Common line

Pneumatic Connection Port 3: Common line

Pilot Air Port 12/14: Common line

Pilot Exhaust Port 82/84: Common line

Exhaust Air Function: With flow control option (via throttle plate on individual valve modules)

Flat Plate Silencer: At one end 

Type of Mounting: H-rail (EN 60715) – horizontal only, or wall mounting 

Valve Manifold Design: Modular, pneumatic valve sizes can be mixed (10 mm and 20 mm)

Tightening Torque – Earthing Screw: 1.3 Nm ±20% 

Tightening Torque – Connecting Plate: 1.8 Nm ±10% 

Tightening Torque – Cover Screw: 0.65 Nm ±10% 

Housing Material: Aluminium alloys, all contain less than 7.5% magnesium (Mg) 

Seals Material: NBR (Elastomer) 

Material Note: RoHS-compliant

Certifications: CE (EU EMC & ATEX), c UL us - Recognized (OL), RCM compliance mark, KC EMC

Country of Origin: Germany

Special Conditions for ATEX Zone 2 Use (Marking X)

Intrinsically Safe Input Option

The MPA-CPI-VI can be equipped with an input module CPX-P-8DE-N-IS, which provides 8 digital NAMUR inputs for intrinsically safe wiring, recognisable by the existing blue identification . The non-intrinsically safe version is CPX-P-8DE-N, recognisable by the lack of blue identification. When the intrinsically safe module is used, the ATEX identification becomes II 3(1)G Ex ec [ia Ga] IIC T4 Gc X .

Compatible Accessories (from Festo documentation)

Ideal For
Large-scale industrial automation systems requiring up to 128 valves via serial linking, applications needing up to 32 valve positions with up to 9 pressure zones, systems requiring ATEX Zone 2 explosion protection (gas), chemical and petrochemical processing, pharmaceutical manufacturing, paint shop environments requiring LABS conformity (VDMA24364-B2-L), semiconductor production, automotive assembly lines, packaging machinery, material handling systems, vacuum handling applications (-0.9 to 10 bar), systems requiring IP65/IP67 washdown protection, and integration with CPX fieldbus systems.

Why Choose Festo MPA-CPI-VI Valve Terminal?
Choose the Festo MPA-CPI-VI for its highly expandable and modular design, featuring high-performance valves in a sturdy metal housing with metal linking, serial linking communication via CPI supporting up to 128 pneumatic valves per terminal, fieldbus connection via CPX, ability to combine 10 mm and 20 mm valve sizes on one terminal, ATEX Zone 2 certification (II 3G Ex nA IIC T4 X Gc), IP65/IP67 protection, CRC 0 corrosion resistance, vacuum capability down to -0.9 bar, up to 32 valve positions with 9 pressure zones, extensive valve functions (2/2, 2x3/2, 3/2, 5/2, 5/3), internal or external pilot air supply, LED status indication, 24V DC operation with ±25% tolerance, max. 10 Hz switching frequency, c UL us, RCM, KC, and CE certifications, RoHS compliance, and German engineering quality. Backed by Festo's comprehensive accessory ecosystem and ATEX-compliant operating conditions with special provisions for electrostatic discharge prevention, strain relief, and pollution degree requirements, this valve terminal delivers reliable, scalable, and safe pneumatic control for demanding industrial automation applications.

Tags
#Festo #MPACPIVI #546280 #ValveTerminal #ValveManifold #CPIFieldbus #MPA #MetalHousing #IP65 #IP67 #CRC0 #ATEX #ExZone2 #cULus #HighlyExpandable #SerialLinking #PneumaticControl #MalaysiaSupplier

Tingnan ang karagdagang mga detalye tungkol sa GREX IND SUPPLY
GREX IND SUPPLY
GREX IND SUPPLY Laboratory & Industrial Equipment Distributor Johor, Malaysia | GREX Industrial Supply