The T-Gage V series offers the latest technologies that will make inspection easier and each model has been built to perform in the roughest of industry conditions.
The T-Gage V series of gauges come with monochrome displays as standard to enhance the user experience functionality. Simple upgrade options are available throughout the life of your gauge.
T-Gage VB
The T-Gage VB is a basic variable velocity gauge with probe and is the most economical model designed to make reliable, accurate thickness readings; primarily on steel structures with access to only one side. Packaged in custom moulded high density casing with a rubber keypad, this gauge offers the end user a simple deliver datalogging function.
T-Gage V
As a mid-range model, the T-Gage V offers the most popular features including echo-to-echo (E-E). These include increase/decrease in gain; vibrate and illuminate the keypad in alarm conditions and with the “transducer attendant” – the end upgradeable options include A/B-Scan capability and the data logging software, Data XLS.
T-Gage VDL
The T-Gage VDL is the top of the range model offering all logger taking up to 50,000 readings, B-Scan and Echo-to-Echo functions. It also includes the Data Management Software, customised pouch belt clip and elasticated band.
Further model options include:
W = A/B Scan
| Feature | Description | T-Gage VB | T-Gage V | T-Gage VDL |
|---|---|---|---|---|
| Thickness Range | 0.20mm – 508mm (0.008 – 20inches) (dependant on material temperature and transducer selection) | |||
| Delay Line Zero Measurement | Auto at power up with listed numeric value. Ideal for correcting delay line wear/curvature & for transducer acoustic drift at elevated temperatures | |||
| Differential Mode | Displays the difference from the actual thickness measurement and a user entered reference value | |||
| Scan Mode | Displays minimum or maximum thickness value at 20 measurements per second | |||
| Hold Mode | Holds display to retain last thickness reading with reverse video display | |||
| Freeze Mode | Freezes display | |||
| Units | Inches/Millimetres/Microseconds | |||
| Gain | Low, Standard or High for varying test conditions | |||
| Differential Mode | Displays the difference from the actual thickness measurement and a user set reference value | — | ||
| Alarms | Maximum depth, vibralarm, beeps and display flashes as well as keypad illumination | — | ||
| Automatic probe wear indicator | Automatically informs the operator to replace the transducer (patent pending) | — | — | |
| Echo-to-Echo | Measures the metal thickness only (ignores paint and coatings) | — | ||
| Non-Encoded B-Scan | Displays a cross section of the test piece | — | — | |
| Data XLS | Datalogging software – Upgrades available | — | — |