ESA series is mainly used for safety protection for stamping machinery, which adopt controller to monitor and output signal of light curtains.
ESA series supports AV110-220V, AC380V voltage and output relay signal. ESA series is designed according to EU safety standard, whose main components are imported.
Good self-diagnosis, easy to operation, and strong anti-vibration ability make ESA series can work in different hazardous equipment, and well protect operators from accident.
.png)
.png)
.png)
.png)
.png)
Specifications :
| Controller Electric Parameter | ||
| Power Supply | AC110V-220V 50/60Hz, AC380V | |
| Capacity | < 15W | |
| Output | Relay contact output | |
| Contact Capacity | 5A, AC250V/DC30V Resistive load | |
| Relay lifespan | ≥10 million times, electrical life is depend on the connected load, can be changed; | |
| Response Time | ≤20ms | |
| Amblent Temperature | -10-55°C No freezing | |
| Ambient Humidity | 20°C, RH ≤ 85% | |
| Insulation Resistance | ≥ 100ΜΩ | |
| Protection Rate | P controller: IP54 | Q controller: IP20 |
| Light Curtain Electric Parameter | ||
| Beam Space | 10mm, 20mm, 40mm | |
| Resolution | 20mm, 30mm, 50mm | |
| Beams | 10mm: 8, 12, 16,...320 | |
| 20mm: 4, 6, 8,...160 | ||
| 40mm: 4, 6, 8,...122 | ||
| Protective Height | Protective height H=(N-1)*beam space, N is beams | |
| Light Wavelength | 940nm | |
| Sensing Distance | 0.1~0.5m, 0.1~2m, 0.1~5m, 0.1~10m, 0.1~20m, 0.1-30m (Remark: please let us know when with reflectivity) | |
| Sensing Method | Through beam | |
| Synchronization | Wire-syn | |
| Against Optical Interference | 10000 Lux (angle>5") | |
| Enclosure Material | Aluminum alloy | |
| Sectional Size | 35 × 50mm | |
| Protection Rate | IP65 | |
| Vibration Resistance | Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X, Y and Z direction | |
.png)
.png)
.png)