			 Type  | 
			
			 DC 3-Wire PNP Models  | 
			
			 DC 2-Wire Models  | 
			
			 DC 2-Wire Models (no polarity)  | 
		||
|---|---|---|---|---|---|
| 
			 Size  | 
			
			 8 dia. (Sensing Head)  | 
		||||
| 
			 Shielding  | 
			
			 Shielded  | 
		||||
| 
			 Model  | 
			
			 E2EC-MC2B1  | 
			
			 E2EC-MC2D1  | 
			
			 E2EC-QC2D1-M1GJ-T  | 
		||
| 
			 Sensing distance  | 
			
			 2 mm ± 15%  | 
			
			 2 mm ± 10%  | 
		|||
| 
			 Set distance  | 
			
			 0 to 1.2 mm  | 
			
			 0 to 1.4 mm  | 
		|||
| 
			 Differential travel  | 
			
			 15% max. of sensing distance  | 
		||||
| 
			 Detectable object  | 
			
			 Ferrous metals (The sensing distance will decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on Data Sheet.)  | 
		||||
| 
			 Standard sensing object  | 
			
			 Iron, 8 × 8 × 1 mm  | 
		||||
| 
			 Response frequency  | 
			
			 100 Hz  | 
		||||
| 
			 Power supply voltage  | 
			
			 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)  | 
		||||
| 
			 Current consumption  | 
			
			 10 mA max.  | 
			
			 ---  | 
		|||
| 
			 Leakage current  | 
			
			 ---  | 
			
			 0.8 mA max.  | 
		|||
| 
			 Control  | 
			
			 Load current  | 
			
			 100 mA max.  | 
			
			 3 to 50 mA  | 
		||
| 
			 Residual voltage  | 
			
			 2 V max. (Load current:  | 
			
			 3 V max. (Load current:  | 
			
			 5 V max. (Load current: 50 mA,  | 
		||
| 
			 Indicators  | 
			
			 Operation indicator (yellow)  | 
			
			 Operation indicator (red), Setting indicator (green)  | 
		|||
| 
			 Operation mode (with  | 
			
			 NO (normally open)  | 
		||||
| 
			 Protection circuits  | 
			
			 Power supply reverse polarity  | 
			
			 Surge suppressor, Load short-circuit protection  | 
		|||
| 
			 Ambient temperature range  | 
			
			 Operating and storage: - 25 to 70 ° C (with no icing or condensation)  | 
		||||
| 
			 Ambient humidity range  | 
			
			 Operating and storage: 35% to 95% (with no condensation)  | 
		||||
| 
			 Temperature influence  | 
			
			 ± 20% max. of sensing distance at 23 ° C in the temperature range of - 25 to 70 ° C  | 
		||||
| 
			 Voltage influence  | 
			
			 ± 5% max. of sensing distance  | 
			
			 ± 1% max. of sensing distance at the rated voltage range in the  | 
		|||
| 
			 Insulation resistance  | 
			
			 50 MΩ min. (at 500 VDC) between current-carrying parts and case  | 
		||||
| 
			 Dielectric strength  | 
			
			 1,000 VAC for 1 min between current carrying-parts and case  | 
		||||
| 
			 Vibration resistance  | 
			
			 Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  | 
		||||
| 
			 Shock resistance  | 
			
			 Destruction: 1,000 m/s2 10 times each in X, Y, Z directions  | 
		||||
| 
			 Degree of protection  | 
			
			 IEC IP67, In-house standards: oil-resistant (For Sensor Head only)  | 
		||||
| 
			 Connection method  | 
			
			 Pre-wired Connector Models (Standard cable length: 2 m)  | 
			
			 Connector Models (Standard cable  | 
		|||
| 
			 Weight (packed state)  | 
			
			 Approx. 65 g  | 
			
			 Approx. 95 g  | 
		|||
| 
			 Materials  | 
			
			 Sensor  | 
			
			 Case  | 
			
			 Stainless steel (SUS303)  | 
			
			 Stainless steel (SUS303)  | 
		|
| 
			 Sensing  | 
			
			 Stainless steel (SUS303) (0.2 mm)  | 
			
			 Stainless steel (SUS303)  | 
		|||
| 
			 Cable  | 
			
			 Polyester elastomer (TPEE) (Shielded)  | 
			
			 Fluoro-rubber (Shielded)  | 
		|||
| 
			 Cable  | 
			
			 Case  | 
			
			 ABS resin  | 
			
			 Stainless steel (SUS303)  | 
		||
| 
			 Cable  | 
			
			 Polyvinyl chloride (PVC)  | 
			
			 Fluorocarbon cable (flame-resistant)  | 
		|||
| 
			 Accessories  | 
			
			 Amplifier Mounting Bracket, instruction manual  | 
		||||