| Model | AX-70TN | AX-130TN | AX-200TN |
| Maximum detection range | 20m | 40m | 60m |
| Maximum arrival range | 200m | 400m | 600m |
| Interruption period | Selectable between 50, 100, 250, and 500 msec. | ||
| Power supply | 10.5 - 28V DC | ||
|
Current consumption (transmitter + receiver) |
38mA (max.) | 41mA (max.) | 45mA (max.) |
| Alarm period | 2 sec.(±1) nominal | ||
| Alarm output | N.C. 28V DC 0.2A max | ||
| Tamper switch | N.C. opens when cover is removed at 28V DC, 0.2A max. | ||
| Operating temperature |
-35°C to +60 °C Use the optional heating unit (HU-3) under the environment of -25°C or less minus. |
||
| Environmental humidity | 95% max. | ||
| Alignment angle | ±90° Horizontal, ±5° Vertical | ||
| Mounting | Wall and pole mounting | ||
| Weight (transmitter+receiver) | 650g | ||
|
Dimensions (H x W x D) |
170mm x 65mm x 69.5mm | ||
| Weatherproof | IP65 | ||