Model: RG-S2910-24GT4XS-E
RUIJIE RG-S2910XS 24-PORT GIGABIT L2+ MANAGED SWITCH WITH SFP+
Ruijie RG-S2910XS-E/P is a collection of next-gen Gigabit switches architected for superior security, switch delivers Non-blocking / wire-speed,high performance and outstanding energy efficiency. The series delivers full Gigabit access and unparalleled scalability to 10G performance. With the all-new hardware architecture and Ruijie’s latest RGOS11.X modular operating system, the RG-S2910XS-E/P switches offer larger table capacity, faster hardware processing performance and a better operation experience than anything previous. In addition, the PoE models in various specifications support all downlink ports running on PoE+ and fulfill high bandwidth demand of 10G uplink. The RG-S2910XS-E/P switches guarantee high-density user access and leading aggregation performance with ease.
KEY FEATURES
| 
				 odel  | 
			
				 RG-S2910-24GT4XS-E  | 
			
				 RG-S2910-48GT4XS-E  | 
			
				 RG-S2910-10GT2SFP-P-E  | 
			
				 RG-S2910C-24GT2XS-HP-E  | 
			
				 RG-S2910C-48GT2XS-HP-E  | 
		
| 
				 Ports  | 
			
				 
					24 10/100/1000BASE-T ports  | 
			
				 
					48 10/100/1000BASE-T ports  | 
			
				 10 10/100/1000BASE-T ports 2 100/1000BASE-X SFP ports (non-combo)  | 
			
				 
					24 10/100/1000BASE-T ports (PoE/PoE+)  | 
			
				 
					48 10/100/1000BASE-T ports (PoE/PoE+)  | 
		
| 
				 Expansion Slots  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 2  | 
			
				 2  | 
		
| 
				 Modular Power Slots  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 2  | 
			
				 2  | 
		
| 
				 Fan Slots  | 
			
				 Fixed  | 
			
				 Fixed  | 
			
				 Fanless  | 
			
				 Fixed  | 
			
				 Fixed  | 
		
| 
				 Expansion Modules  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 
					M2910-01XS  | 
			
				 
					M2910-01XS  | 
		
| 
				 Management Ports  | 
			
				 1 console port  | 
			
				 1 console port  | 
			
				 1 console port  | 
			
				 
					1 console port  | 
			
				 
					1 console port  | 
		
| 
				 Switching Capacity  | 
			
				 264Gbps  | 
			
				 264Gbps  | 
			
				 256Gbps  | 
			
				 264Gbps  | 
			
				 264Gbps  | 
		
| 
				 Packet Forwarding Rate  | 
			
				 96Mpps  | 
			
				 132Mpps  | 
			
				 18Mpps  | 
			
				 96Mpps  | 
			
				 132Mpps  | 
		
| 
				 Max. Number of 10GE Ports  | 
			
				 4  | 
			
				 4  | 
			
				 N/A  | 
			
				 4  | 
			
				 4  | 
		
| 
				 PoE  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking  | 
			
				 IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking  | 
			
				 IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking  | 
		
| 
				 Port Buffer  | 
			
				 1.5MB  | 
		||||
| 
				 RAM  | 
			
				 512MB  | 
		||||
| 
				 ARP Table  | 
			
				 1,000  | 
			
				 1,000  | 
			
				 500  | 
			
				 1,000  | 
			
				 1,000  | 
		
| 
				 MAC Address  | 
			
				 16K  | 
		||||
| 
				 
					Routing Table Size  | 
			
				 500 (IPv4/IPv6)  | 
			
				 500 (IPv4/IPv6)  | 
			
				 64 (IPv4/IPv6)  | 
			
				 500 (IPv4/IPv6)  | 
			
				 500 (IPv4/IPv6)  | 
		
| 
				 ACL Entries  | 
			
				 
					In: 1,500  | 
			
				 
					In: 1,500  | 
			
				 In: 750 Out: N/A  | 
			
				 
					In: 1,500  | 
			
				 
					In: 1,500  | 
		
| 
				 VLAN  | 
			
				 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN  | 
		||||
| 
				 QinQ  | 
			
				 Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching  | 
		||||
| 
				 Link Aggregation  | 
			
				 AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance  | 
		||||
| 
				 Port Mirroring  | 
			
				 Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN # RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring  | 
		||||
| 
				 Spanning Tree Protocols  | 
			
				 IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG)  | 
		||||
| 
				 DHCP  | 
			
				 DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82  | 
		||||
| 
				 Multiple Spanning Tree Protocol (MSTP) Instances  | 
			
				 64  | 
		||||
| 
				 Maximum Aggregation Port (AP)  | 
			
				 128  | 
		||||
| 
				 SDN  | 
			
				 OpenFlow 1.0 & 1.3  | 
		||||
| 
				 VSU (Virtual Switch Unit)  | 
			
				 Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports # All models support the features above except RG-S2910-10GT2SFP-P-E  | 
		||||
| 
				 Zero Configuration  | 
			
				 CWMP(TR069)  | 
		||||
| 
				 L2 Features  | 
			
				 MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel  | 
		||||
| 
				 Layer 2 Protocols  | 
			
				 IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s  | 
		||||
| 
				 IPv4 Features  | 
			
				 Ping, Traceroute  | 
		||||
| 
				 IPv6 Features  | 
			
				 ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address  | 
		||||
| 
				 IPv4 Routing Protocols  | 
			
				 Static Routing, RIP, OSPF v1/v2  | 
		||||
| 
				 Basic IPv6 Protocols  | 
			
				 IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert  | 
		||||
| 
				 IPv6 Routing Protocols  | 
			
				 Static routing, RIPng, OSPF v3  | 
		||||
| 
				 G.8032  | 
			
				 Support  | 
		||||
| 
				 ACL  | 
			
				 Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL  | 
		||||
| 
				 QoS  | 
			
				 802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS  | 
		||||
| 
				 Reliability  | 
			
				 VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)  | 
			
				 VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)  | 
			
				 RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)  | 
			
				 VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module  | 
			
				 VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module  | 
		
| 
				 EEE Format  | 
			
				 Support IEEE 802.3az standard  | 
		||||
| 
				 Security  | 
			
				 Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI)  | 
		||||
| 
				 Manageability  | 
			
				 SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS # RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web 
  | 
		||||
| 
				 Hot Patch  | 
			
				 Support  | 
		||||
| 
				 Smart Temperature Control  | 
			
				 Auto fan speed adjustment; Fan malfunction alerts; Fan status check # All models support the features above except RG-S2910-10GT2SFP-P-E 
  | 
		||||
| 
				 Smart Power Supply  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 Support power control and management  | 
			
				 Support power control and management  | 
		
| 
				 Other Protocols  | 
			
				 FTP, TFTP, DNS client, DNS static  | 
		||||
| 
				 
					Dimensions  | 
			
				 440 × 260 × 43.6  | 
			
				 440 × 260 × 43.6  | 
			
				 340 × 260 × 44  | 
			
				 440 × 320 × 44  | 
			
				 440 × 360 × 44  | 
		
| 
				 Rack Height  | 
			
				 1RU  | 
		||||
| 
				 Weight  | 
			
				 ≤3.5kg  | 
			
				 ≤4kg  | 
			
				 <2.5kg  | 
			
				 5.8kg (gross weight)  | 
			
				 6.8kg (gross weight)  | 
		
| 
				 MTBF (hours)  | 
			
				 >200K  | 
		||||
| 
				 Lightning Protection on Power Port  | 
			
				 Common Mode 6KV/Differential Mode 6KV  | 
			
				 Common Mode 6KV/Differential Mode 6KV  | 
			
				 Common Mode 6KV/Differential Mode 6KV  | 
			
				 Common Mode 4KV/Differential Mode 2K  | 
			
				 Common Mode 4KV/Differential Mode 2K  | 
		
| 
				 Lightening Protection on Communication Port  | 
			
				 Common Mode 6KV  | 
		||||
| 
				 Power Supply  | 
			
				 
					AC input:  | 
			
				 
					AC input:  | 
			
				 AC input: Rated voltage range: 100V to 240V AC Maximum voltage range: 90V to 264V AC Frequency: 50/60Hz Rated current: 2A 
 
					HVDC input:  | 
			
				 
					AC power (RG-M5000E-AC500P):  | 
			
				 
					AC power (RG-M5000E-AC500P):  | 
		
| 
				 Power Consumption  | 
			
				 24W  | 
			
				 50W  | 
			
				 165W (with 8-port PoE or 4-port PoE+)  | 
			
				 850W (with 24-port PoE+)  | 
			
				 1700W (with 48-port PoE+)  | 
		
| 
				 PoE Power  | 
			
				 N/A  | 
			
				 N/A  | 
			
				 125W  | 
			
				 
					RG-M5000E-AC500P: 370W  | 
			
				 
					RG-M5000E-AC500P: 370W  | 
		
| 
				 Safety Standards  | 
			
				 IEC 60950-1, EN 60950-1  | 
		||||
| 
				 Emission Standards  | 
			
				 EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11  | 
		||||
| 
				 Temperature  | 
			
				 Operating temperature: 0°C to 50°C  | 
			
				 Operating temperature: 0°C to 50°C  | 
			
				 Operating temperature: 0°C to 45°C  | 
			
				 Operating temperature: 0°C to 50°C  | 
			
				 Operating temperature: 0°C to 50°C  | 
		
| 
				 Storage temperature: -40°C to 70°C  | 
		|||||
| 
				 Humidity  | 
			
				 Operating humidity: 10% to 90%RH  | 
		||||
| 
				 Storage humidity: 5% to 95%RH  | 
		|||||
| 
				 Operating Altitude  | 
			
				 -500m to 5,000m  | 
		||||
















Malaysia