Description
Schneider Electric PowerLogic PM3000 Series
PowerLogic PM3000 Series DIN Rail Power Meters
Schneider Electric PowerLogic PM3000 Series meters are cost-effective DIN rail power meters for electrical installation monitoring, sub-metering, cost allocation and basic network management.
The PM3000 Series includes PM3200, PM3210, PM3250 and PM3255 variants. All models provide multi-function electrical measurement, 1A / 5A CT input, VT input, 4-tariff capability, backlit display, min / max data and IEC 61557-12 PMD performance alignment.
PM3200 / PM3210 / PM3250 / PM3255
DIN Rail Mount
1A / 5A CT Input
4-Tariff Registers
Pulse / RS485 Options
PM3255 Digital I/O
IoTWatt 4.0 Ready
Product Overview
PowerLogic PM3000 is suitable for projects that require DIN rail-mounted metering with reliable local display and selectable communication options. It provides the main electrical measurements required to understand feeder behaviour, circuit consumption, demand, energy import / export and load patterns.
The series is useful for sub-metering and cost allocation because it supports multi-tariff energy registers, WAGES pulse collection on supported models, RS485 Modbus communication on communication variants and demand / energy logs on higher variants.
Positioning: Use PM3000 where a DIN rail Schneider Electric power meter is required for basic monitoring, cost allocation, sub-metering, energy management and IoTWatt 4.0 integration.
Why PM3000 Matters
PM3000 provides a practical DIN rail metering option for compact panels, distribution boards, tenant metering and gateway-based energy monitoring systems.
- DIN rail format
- Sub-metering
- Cost allocation
- 4-tariff metering
- Pulse output option
- RS485 Modbus option
- PM3255 digital I/O
Typical Monitoring Architecture
PM3000 meters are installed on DIN rail inside electrical panels. Depending on the selected variant, the meter can provide local display only, pulse output, RS485 Modbus communication, digital input / output functions and alarm integration.
1
CT / VT Inputs
Feeder or panel measurement point.
2
PM3000 DIN Meter
Energy, power and demand readings.
3
Pulse / RS485
Pulse output or Modbus RTU data.
4
Gateway / EMS
Remote data collection.
5
IoTWatt 4.0
Dashboards, reports and analytics.
Variant Part Numbers and Selection
| Commercial Reference |
Model |
Description |
Main Features |
Recommended Use |
| METSEPM3200 |
PM3200 |
Basic DIN rail power meter. |
CT input 1A / 5A, VT input, multi-tariff, local backlit display, instantaneous values, energy values, present demand and min / max values. |
Basic DIN rail local metering where remote communication is not required. |
| METSEPM3210 |
PM3210 |
DIN rail power meter with pulse output. |
PM3200 functions plus pulse output for kWh pulse collection and basic external energy monitoring. |
Sub-metering points where simple pulse-based kWh monitoring is required. |
| METSEPM3250 |
PM3250 |
DIN rail power meter with RS485 port. |
RS485 Modbus communication, THD current and voltage, alarms with timestamping, min / max values, demand and energy monitoring. |
DIN rail Modbus metering for EMS, BMS, SCADA, gateway or IoTWatt 4.0 integration. |
| METSEPM3255 |
PM3255 |
DIN rail power meter with RS485 plus 2DI / 2DO. |
PM3250 functions plus 2 digital inputs, 2 digital outputs, WAGES pulse collection, external status, tariff control, alarm output and kWh pulse functions. |
Best PM3000 variant for integrated energy monitoring, WAGES pulse collection, digital status monitoring and IoTWatt 4.0 gateway projects. |
Selection note: For new IoTWatt 4.0 integration, PM3250 or PM3255 is normally preferred because RS485 Modbus provides richer live data than pulse-only monitoring. Select PM3255 when digital inputs, digital outputs, WAGES pulses or additional alarms are required.
Feature Comparison
| Feature |
PM3200 |
PM3210 |
PM3250 |
PM3255 |
| DIN Rail Mounting |
Yes |
Yes |
Yes |
Yes |
| CT Input |
1A / 5A |
1A / 5A |
1A / 5A |
1A / 5A |
| VT Input |
Yes |
Yes |
Yes |
Yes |
| Multi-Tariff |
4 tariffs |
4 tariffs |
4 tariffs |
4 tariffs |
| Backlit Display |
Yes |
Yes |
Yes |
Yes |
| Instantaneous Values |
Current, voltage, power and power factor |
Current, voltage, power and power factor |
Current, voltage, power and power factor |
Current, voltage, power and power factor |
| Energy Values |
Active, reactive and apparent energy; import and export |
Active, reactive and apparent energy; import and export |
Active, reactive and apparent energy; import and export |
Active, reactive and apparent energy; import and export |
| THD Current and Voltage |
- |
Limited / model dependent |
Yes |
Yes |
| Pulse Output |
No |
Yes |
No |
Digital output available |
| RS485 Modbus |
No |
No |
Yes |
Yes |
| Digital Inputs / Outputs |
No |
Pulse output focused |
No |
2DI / 2DO |
| Typical Use |
Local metering |
Pulse-based kWh monitoring |
RS485 Modbus metering |
RS485 + WAGES / I/O monitoring |
Key Features at a Glance
DIN Rail Format
Compact DIN rail design for metering panels, control panels and distribution boards.
Multi-Function Metering
Measures current, voltage, power, power factor, energy and demand values.
1A / 5A CT Input
Supports standard CT secondary inputs for LV and HV metering applications.
VT Input
Suitable for systems requiring voltage transformer input, including HV monitoring applications.
4-Tariff Capability
Separates energy consumption into four tariff registers for tariff or source-based tracking.
Backlit Display
Provides local electrical parameter visibility for panel operators and maintenance teams.
RS485 Modbus Options
PM3250 and PM3255 support Modbus communication for EMS, BMS, SCADA and IoTWatt 4.0.
Digital I/O on PM3255
2 digital inputs and 2 digital outputs for WAGES pulse collection, status and alarm functions.
Cost Allocation Support
Supports tenant metering, feeder consumption, peak / off-peak review and energy cost allocation.
Multi-Tariff and WAGES Monitoring
PM3000 meters support four tariff registers. Tariff switching can be controlled by digital inputs, internal clock or communication depending on the model and configuration.
| Function |
Purpose |
Typical Use |
| 4-Tariff Registers |
Separates kWh consumption into different tariff registers. |
Peak / off-peak monitoring, weekday / weekend tracking and tariff analysis. |
| External Tariff Control |
Uses a digital input or external control signal to change tariff register. |
PLC or utility tariff signal integration. |
| Internal Clock Tariff Control |
Uses the meter clock for scheduled tariff operation. |
Time-of-use tariff tracking without a communication system. |
| Tariff Control by Communication |
Allows tariff selection through Modbus on supported variants. |
EMS, BMS, SCADA or IoTWatt 4.0 driven tariff logic. |
| WAGES Pulse Collection |
Digital inputs can collect pulses from external utility meters. |
Useful on PM3255 for water, air, gas, electricity or steam pulse collection. |
Applications and Best-Fit Sites
- Distribution board metering
- DIN rail metering panels
- Feeder sub-metering
- Tenant metering
- Cost allocation
- Utility pulse collection
- WAGES monitoring
- Tariff-based monitoring
- EMS / BMS / SCADA
- IoTWatt 4.0
- Energy audit evidence
- EECA reporting support
Typical Measured Parameters
| Parameter Group |
Typical Measurements |
| Voltage |
Per-phase and average voltage values depending on wiring and VT configuration. |
| Current |
Per-phase and average current values using 1A / 5A CT secondary input. |
| Power |
Active, reactive and apparent power, total and per phase. |
| Energy |
Active, reactive and apparent energy, including import and export values. |
| Power Factor |
Total and per-phase power factor values. |
| Demand |
Current demand and power demand, present and peak depending on model. |
| Power Quality |
THD current and voltage on supported variants. |
| Logs and Alarms |
Min / max values, power demand logs, energy logs and alarms depending on model. |
Communication and Integration Selection
| Integration Requirement |
Recommended Variant |
Reason |
| Local display only |
PM3200 / METSEPM3200 |
Basic power meter for local DIN rail metering. |
| Pulse-based kWh monitoring |
PM3210 / METSEPM3210 |
Pulse output allows external kWh counting through pulse counter, PLC, I/O module or gateway. |
| RS485 Modbus energy monitoring |
PM3250 / METSEPM3250 |
RS485 Modbus port supports digital meter data collection. |
| RS485 + digital I/O + WAGES |
PM3255 / METSEPM3255 |
Best option where Modbus data, digital inputs, digital outputs, WAGES pulse collection or alarm output are required. |
| IoTWatt 4.0 energy dashboards |
PM3250 or PM3255 |
RS485 Modbus provides richer values than pulse-only energy monitoring. |
| IoTWatt 4.0 basic kWh trend only |
PM3210 |
Pulse output can be used for simple energy counting where only kWh trend is required. |
Integration with IoTWatt 4.0
IoTWatt 4.0 can use PM3000 data for energy dashboards, consumption trends, load profiling, tariff-based energy review, demand monitoring, sub-metering and digital energy audit workflows.
- kWh and kW monitoring
- Voltage and current trends
- Power factor review
- Demand monitoring
- Sub-metering dashboards
- 4-tariff energy review
- WAGES pulse collection
- Energy baseline support
- Digital energy audit data
- EECA reporting support
Integration note: PM3250 and PM3255 can be connected to IoTWatt 4.0 through RS485 using a compatible Modbus gateway such as RS2LAN, RS2MQTT or RS2WLAN. PM3210 can be used for pulse-based energy monitoring through a compatible pulse input module.
Recommended Deployment Checklist
- Select PM3200 / PM3210 / PM3250 / PM3255
- Confirm local / pulse / RS485 / digital I/O need
- Confirm DIN rail space
- Confirm CT secondary 1A or 5A
- Confirm CT ratio and class
- Confirm CT burden and polarity
- Confirm VT requirement
- Confirm wiring configuration
- Confirm tariff control method
- Confirm RS485 settings
- Confirm pulse scaling
- Confirm PM3255 I/O usage
- Confirm IoTWatt 4.0 integration
- Test display, pulse, I/O and communication
PM3000 Supply, Variant Selection, Commissioning and IoTWatt 4.0 Integration
Saturn Pyro supports Schneider Electric PowerLogic PM3000 Series DIN rail power meters for variant selection, supply, installation support, RS485 Modbus integration, pulse monitoring, WAGES pulse collection, EMS / BMS / SCADA connectivity and IoTWatt 4.0 digital energy audit projects in Malaysia.
Enquire Now
More detail about Saturn Pyro Sdn Bhd