4 ranges, wide dynamic range, high speed sampling and high accuracy.
| Equipment name | CT-9000 Battery Testing System |
|---|---|
| Voltage | |
| Output range / channel | Charge:0V ~ 5V Discharge:0V ~ 5V |
| Minimum discharge voltage | 0V |
| Accuracy | ± 0.02% of F.S. / range |
| Stability | 0.01% of F.S. |
| Current | |
| Output range / channel | Range1: 0.015mA ~ 15mA Range2: 15mA ~ 150mA Range3: 150mA ~ 1500mA Range4: 1500mA ~ 15A |
| Accuracy | ± 0.02% of F.S. Range1: ±3μA Range2: ±30μA Range3: ±300μA Range4: ±3mA |
| Stability | ±0.01% of F.S. |
| Power | |
| Output power / channel | 75W |
| Stability | ± 0.01% of F.S. |
| Time | |
| Current response time | ≤ 150μS (10% to 90% or 90% to 10%) |
| Working step time | ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms) |