Model DSS-7
Gas Flow Capacity : 7,000 l/hour
Gas Inlet Pressure : 0.2 to 1.0 kg/cm²
Use
Supply clean water from the Water Inlet to the level line of Water Level Window. If water exceeds in , open the Drain Valve and adjust it to the level line.
Function
When back fire occurs, exploded gas breaks Rupture Disc Plate and at the same time, the Flashback Cut-off Valve will be closed automatically. In case of counter flow of gas, the Counter-flow Preventer will be closed by pressure of gas.
Caution
| Type | DSS-7 | ||||
| Flow Capacity | 7m³/h | Outlet | PF1/2 Female | Weight | 11kg |
| Inlet | PT1/2 Female | Height | 600mm | - | |
Malaysia