Standard: ASTM C230
Consistency,Flow, Workable Life & Water Vapour
Permeability of Mortars
Used to determining the consistency of mortar & building line. Offering ASTM & EN standard, manual & motorized. A specimen contained in a cone mould is placed on a metal surface which is then raised & dropped from a known height after releasing the specimen from the mould.
Technical Specifications
| Model Number | NL 3016 X / 001 | NL 3016 X / 002 |
| Type | Motorized Operated | Hand Operated |
| Dimension (mm) | 310 (L) x 255 (W) x 245 (H) | |
| Diameter of Table | 254 mm Brass | |
| Height of Drop | 12.7 mm | |
| Flow Table Weight | 4.08 kg | |
| Approx. Weight | 14.6 kg | |
| Power | - | 220 V, 1 ph, 50 / 60 Hz |