Description
View old post here.
LV 3/11 - LVT 15/11
The models LV 3/11 - LVT 15/11 are especially designed for ashing in the laboratory. A special air intake and exhaust system allows air exchange of more than 6 times per minute. Incoming air is preheated to ensure a good temperature uniformity.
-
Tmax 1100 °C
-
Heating from two sides
-
Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
-
Air exchange of more than 6 times per minute
-
Good temperature uniformity due to preheating of incoming air
-
Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
-
Housing made of sheets of textured stainless steel
-
Dual shell housing for low external temperatures and stability
-
Optional flap door (LV) which can be used as work platform or lift door (LVT) with hot surface facing away from the operator
-
Solid state relays provide for lownoise operation
-
Defined application within the constraints of the operating instructions
-
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional Equipment
-
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
-
Observation hole in the door
-
Process control and documentation via VCD software package for monitoring, documentation and control
|
Model Flap door |
Tmax °C |
Inner dimensions in mm |
Volume in l |
Outer dimensions in mm |
Connected load kW |
Electrical connection |
Weight in kg |
Minutes to Tmax² |
|
W |
D |
H |
W |
D |
H |
|
LV 3/11 |
1100 |
160 |
140 |
100 |
3 |
385 |
360 |
735 |
1.2 |
single-phase |
20 |
120 |
|
LV 5/11 |
1100 |
200 |
170 |
130 |
5 |
385 |
420 |
790 |
2.4 |
single-phase |
35 |
120 |
|
LV 9/11 |
1100 |
230 |
240 |
170 |
9 |
415 |
485 |
845 |
3.0 |
single-phase |
45 |
120 |
|
LV 15/11 |
1100 |
230 |
340 |
170 |
15 |
415 |
585 |
845 |
3.5 |
single-phase |
55 |
120 |
|
Model Lift door |
Tmax °C |
Inner dimensions in mm |
Volume in l |
Outer dimensions in mm |
Connected load kW |
Electrical connection |
Weight in kg |
Minutes to Tmax² |
|
W |
D |
H |
W |
D |
H |
|
LVT 3/11 |
1100 |
160 |
140 |
100 |
3 |
385 |
360 |
735 |
1.2 |
single-phase |
20 |
120 |
|
LVT 5/11 |
1100 |
200 |
170 |
130 |
5 |
385 |
420 |
790 |
2.4 |
single-phase |
35 |
120 |
|
LVT 9/11 |
1100 |
230 |
240 |
170 |
9 |
415 |
485 |
845 |
3.0 |
single-phase |
45 |
120 |
|
LVT15/11 |
1100 |
230 |
340 |
170 |
15 |
415 |
585 |
845 |
3.5 |
single-phase |
55 |
120 |
More detail about Obsnap Instruments Sdn Bhd