Description
QEED Single-Phase AC/DC Network Analyzer
QI-POWER-485 Single Phase AC/DC Power & Energy Meter
The QEED QI-POWER-485 is a single-phase AC/DC TRMS power and energy meter with RS485 Modbus RTU communication. It measures current, voltage, active power, reactive power, apparent power, peak values, frequency, power factor, bidirectional energy and THD.
It is suitable for applications where both AC and DC energy must be monitored from one compact device, including photovoltaic systems, inverters, UPS, battery systems, machine tools, charging systems, control panels and energy management installations.
Measurement
Single-phase AC/DC TRMS
Communication
RS485 Modbus RTU
Energy
Bidirectional kWh measurement
Family Range
50A, 100A and 300A versions
Overview
QI-POWER-485 is designed for direct single-phase current and voltage measurement without the need for external current transformers in standard applications. The device provides Modbus RTU data for PLC, SCADA, EMS, BMS, datalogger, Modbus gateway, IoT gateway and IoTWatt 4.0 integration.
The product family includes different current ratings, including 50A, 100A and 300A versions. This page covers the general QI-POWER-485 family and is suitable where the exact current rating will be selected based on the project requirement.
Positioning: Compact single-phase AC/DC Modbus power meter for energy monitoring, PV, UPS, inverter, battery, machine and IoTWatt 4.0 applications.
Key Features
AC/DC Energy Measurement
Measures both AC and DC energy with bidirectional energy visibility.
TRMS Measurement
Measures TRMS current and voltage, suitable for non-ideal electrical waveforms.
RS485 Modbus RTU
Direct communication to Modbus master devices, PLC, SCADA, EMS, BMS and IoT gateways.
THD Available
THD value is available through RS485 for basic waveform distortion visibility.
DIN Rail Mounting
Compact mounting for electrical panels, control panels and monitoring enclosures.
Software Configurable
Configurable through FACILE / Q-WIZARD software or directly through Modbus registers.
Measurements Available via RS485
| Measurement Group |
Available Values |
| Current |
IRMS, Ipeak |
| Voltage |
VRMS, Vpeak |
| Power |
Active power W, reactive power VAR and apparent power VA |
| Energy |
Bidirectional kWh, positive and negative energy |
| Power Factor |
Cosφ |
| Frequency |
Frequency measurement |
| Power Quality |
THD, voltage peak and current peak visibility |
QI-POWER-485 Family
| Model |
Current Measurement |
Voltage Measurement |
Use Case |
| QI-POWER-485 |
50A AC/DC |
Up to 800Vac / 1000Vdc |
General single-phase AC/DC energy monitoring |
| QI-POWER-485-100 |
100A AC/DC |
Up to 800Vac / 1000Vdc |
Higher current single-phase AC/DC monitoring |
| QI-POWER-485-300 |
300A AC / 400A DC |
Up to 800Vac / 1000Vdc |
High current AC/DC monitoring, UPS, PV, inverter and industrial systems |
| QI-POWER-485-LV |
50A AC/DC |
Up to 80Vac / 100Vdc |
Low-voltage AC/DC systems, battery and DC motor applications |
| QI-POWER-485-300-LV |
300A AC / 400A DC |
Up to 80Vac / 100Vdc |
High-current low-voltage AC/DC monitoring |
Selection note: Confirm the required current rating and voltage range before ordering. Use the LV versions for low-voltage AC/DC applications up to 80Vac / 100Vdc.
Technical Highlights
| Parameter |
Specification |
| Product Type |
Single-phase AC/DC TRMS power and energy meter |
| Measurement Type |
RMS or DC measurement |
| Current Measurement |
50A, 100A or 300A AC / 400A DC depending on model |
| Voltage Measurement |
Up to 800Vac / 1000Vdc for standard versions |
| Power Supply |
9 to 30Vdc with polarity reversal and over-temperature protection |
| Accuracy Reference |
Voltage, current and active power: <0.5% F.S.; energy: ±1% of reading; Vpeak / Ipeak: ±5% F.S. |
| Output |
RS485 Modbus RTU |
| Configuration |
FACILE / Q-WIZARD software or Modbus register map |
| Mounting |
DIN rail mounting, horizontal or vertical depending on model installation |
| Isolation |
4kV galvanic isolation for voltage input |
Applications
Photovoltaic Systems
Monitor AC/DC power and energy, parallel string voltage and current, inverter-side values and generated energy.
Energy Management
Send current, voltage, power and energy values directly to Modbus master devices and EMS platforms.
UPS and Battery Systems
Monitor AC/DC power, energy flow and bidirectional energy in backup power and battery systems.
Machine Tools
Measure machine power, current, voltage and energy for production and maintenance visibility.
Charging Systems
Support AC/DC monitoring in charging columns and related electrical infrastructure.
IoTWatt 4.0
Can be integrated through RS485 gateways into IoTWatt 4.0 dashboards, reports and analytics.
Configuration
QI-POWER-485 can be configured using an RS485-USB serial link and FACILE / Q-WIZARD software. It can also be configured directly from a Modbus master system using the register map.
- Set Modbus address and communication parameters
- Set baud rate and communication delay
- Configure CT and VT transformation ratio when required
- Select RMS or DC measurement mode
- Adjust filter from faster response to more stable measurement
- Select frequency measurement on current channel when needed
- Set minimum current cut-off threshold
- Set minimum power cut-off threshold
- Save energy counters on internal flash memory
- Restore factory default settings
Commissioning note: Correct Modbus address, baud rate, scaling and measurement mode must be confirmed before connecting the meter to a permanent monitoring or energy management platform.
FACILE / Q-WIZARD Software Functions
| Function |
Purpose |
| Type of Measure |
Select RMS or DC-only measurement behaviour and polarity handling. |
| Save on Energy Flash |
Allows energy counters to be saved directly on the device flash memory. |
| Report of Transformation |
Defines current and voltage transformation ratio. Default ratio is 1:1. |
| Filter |
Adjusts reading response for faster output or more stable measurement. |
| Minimum Current Threshold |
Sets current cut-off value. Below this value the device reads zero. |
| Minimum Power Threshold |
Sets power cut-off value. Below this value the device reads zero. |
| Factory Default |
Restores the device to default configuration. |
RS485 Modbus Integration
QI-POWER-485 can be connected into an RS485 Modbus RTU network and read by PLC, SCADA, EMS, BMS, Modbus gateway, datalogger, IoT gateway or IoTWatt 4.0. It is suitable for both temporary commissioning checks and permanent energy monitoring installations.
- Use unique Modbus addresses for multiple meters on one RS485 bus
- Verify baud rate, parity and Modbus response delay during commissioning
- Confirm voltage, current and energy scaling before live monitoring
- Use USB-RS485 converter for configuration and troubleshooting
- Use RS485 gateway for cloud monitoring and IoTWatt 4.0 integration
QI-POWER-485 Supply and Integration
Saturn Pyro supports QEED QI-POWER-485 single-phase AC/DC power meters for photovoltaic systems, inverters, UPS, batteries, machine tools, charging systems, RS485 Modbus integration, IoT gateway connection and IoTWatt 4.0 projects in Malaysia.
Enquire Now
More detail about Saturn Pyro Sdn Bhd