Flexible Duct Connection

Flexible Duct Connection

分类: AHU Ducting & Terminal Connection Setup 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

AHU Ducting & Terminal Connection Setup: Flexible Duct Connection

In the 2026 Malaysian engineering landscape, the Flexible Duct Connection serves as the final "soft link" between the rigid secondary ductwork and the terminal device (such as a Ceiling Air Diffuser or VAV box). Under MS 1525:2024 and SMACNA 2026 standards, this connection is critical for isolating mechanical noise and allowing for precision alignment in congested ceiling voids.

At EKG (Malaysia) SDN BHD, we engineer flexible connections to be Sterile, Silent, and Statutory-Compliant, ensuring they do not become a source of energy-wasting friction or acoustic distress.


1. The Statutory Framework: EECA 2024 & Thermal Integrity

Since the enforcement of the Energy Efficiency and Conservation Act (EECA) 2024, flexible ducts are no longer treated as "disposable" components. They must meet strict thermal and leakage benchmarks.


2. Engineering for Low Static Pressure

The most common cause of high Specific Fan Power (SFP) in Malaysian buildings is poorly installed flexible ducting. EKG adheres to the "Short & Straight" protocol:

Installation Rule 2026 Standard Engineering Purpose
Maximum Length 1.5 to 2.0 Meters Prevents excessive friction and "sagging" that forces the VFD to ramp up.
Bending Radius 1.5 x Diameter (Min) Ensures smooth airflow and prevents high-frequency "hissing" noise.
Slack Management Fully Extended "Compressed" flex duct can increase static pressure by up to 400%.
Support Spacing Every 1.0 Meter Prevents the duct from resting on ceiling T-bars or sharp electrical trays.

3. Acoustic Performance: NC 30-35

Flexible ducts act as a secondary "muffler." By decoupling the rigid metal duct from the diffuser, they prevent the transmission of mechanical vibration into the occupied zone.

  1. Vibration Isolation: The flexible core absorbs the minor pulsations from the VFD-driven AHU, ensuring executive areas maintain a Noise Criteria (NC) of 30 to 35.

  2. Velocity Control: We size the flexible connection for a maximum velocity of 3.5 m/s. If the air moves too fast through the ribbed internal core of a flex duct, it generates a turbulent "whistle" that is a common cause of occupant complaints.


4. The "Fire Mode" Statutory Protocol

Flexible duct connections must comply with BOMBA (JBPM) 2026 fire safety standards, especially regarding smoke toxicity and flame spread.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your flexible ducting causing drafts, noise, or high energy bills?

Contact EKG (Malaysia) SDN BHD today for a specialized Terminal Connection & Airflow Efficiency Audit.

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD