High-Rise Smoke Spill AHU Solutions

High-Rise Smoke Spill AHU Solutions

分类: BOMBA Certified AHU Installation 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

High-Rise Smoke Spill AHU Solutions: Statutory Standards 2026

In the 2026 Malaysian high-rise landscape, Smoke Spill AHU Solutions (Mechanical Smoke Extraction) are specialized mechanical systems governed by the Uniform Building By-Laws (UBBL) 2026 and MS 1780:2017/2026. Unlike standard AHUs that shut down during a fire, Smoke Spill systems are engineered to perform under extreme thermal loads to extract toxic fumes from lobbies, corridors, and large floor plates, ensuring safe passage for occupants.

At EKG (Malaysia) SDN BHD, we design these systems to be Sterile, Silent, and Statutory-Compliant, bridging the gap between comfort cooling and life-safety extraction.


1. The Statutory Framework: Smoke Spill vs. Purging

Under the 2026 regulations, a clear distinction is made between Smoke Purging (clearing smoke post-fire) and Smoke Spill (active extraction during a fire).


2. High-Temperature Engineering Components

A high-rise smoke spill solution requires hardware that goes beyond standard HVAC specifications.

Component Smoke Spill Requirement Engineering Purpose
High-Temp Motor Class H Insulation / IP55 Prevents the motor from seizing or burning out at 250°C.
Fire-Rated Ducting MS 2586:2026 (1.2mm min) Prevents duct collapse and smoke leakage into "safe" zones.
Variable Frequency Drive (VFD) Dedicated "Fire Mode" Bypasses internal motor protections to keep the fan running until failure.
FR Cabling MS 2116 Class C Ensures power supply is maintained throughout the evacuation window.

3. Integrated "Emergency Mode" Protocol

In a high-rise fire event, the EKG Smoke Spill Protocol follows an automated sequence:

  1. Fire Signal Trigger: The Fire Alarm Monitoring System (FAMS) detects smoke and sends a signal to the BMS/Fire Panel.

  2. AC Shutdown / Spill Initiation: Standard AHUs in the building trigger an Automatic Fire Signal AHU Shut-off, while the Smoke Spill fan ramps up to 100% capacity.

  3. Make-Up Air Interlock: To prevent a "vacuum" effect—which would make fire doors impossible to open—the extraction fan is interlocked with Motorized Fresh Air Louvers to introduce replacement air.

  4. Pressurization Balance: In KL high-rises, this works with Stairwell Pressurization Systems (governed by MS 1472) to keep escape stairs smoke-free.


4. Why Partner with EKG (Malaysia) SDN BHD?

Is your high-rise smoke spill system a life-safety asset or a statutory liability? Contact EKG (Malaysia) SDN BHD today for a specialized High-Rise Smoke Control Audit & Design.

Are you designing the smoke spill system for a new residential high-rise or a commercial Grade-A office tower?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD