AHU Safety Permit

分类: BOMBA Certified AHU Installation 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

BOMBA Certified AHU Installation: Statutory Safety Standards 2026

In the 2026 Malaysian regulatory landscape, BOMBA Certified AHU Installation represents a critical intersection between mechanical performance and life safety. Under the Fire Services Act 1988 (Act 341) and the Uniform Building By-Laws (UBBL) 2026, Air Handling Units (AHUs) are no longer viewed merely as cooling assets; they are primary components of the building’s Active Fire Protection system.

At EKG (Malaysia) SDN BHD, we manage the specialized BOMBA Safety Permit process, ensuring your AHU installation is Sterile, Silent, and Statutory-Compliant.


1. The AHU Safety Permit: Statutory Mandates

The AHU Safety Permit is a mandatory prerequisite for obtaining the BOMBA Clearance Letter (Surat Pelepasan BOMBA), which is essential for the building's Certificate of Completion and Compliance (CCC).


2. Engineering Standards for BOMBA Certification

To secure a BOMBA Safety Permit, the physical installation must meet specific fire-safety engineering benchmarks:

Component BOMBA Requirement Engineering Purpose
Casing Material Non-Combustible (Class 0) Ensures the AHU does not contribute to the fire load of the plant room.
Insulation Fire-Rated Closed Cell Prevents the spread of flame and smoke within the double-skin panels.
Wiring & Conduit FR (Fire Resistant) Cables Maintains sensor signal integrity during high-heat events.
Access Clearance 1000mm Frontal Access Allows fire officers and maintenance crews safe entry during emergencies.

3. The BOMBA Site Inspection & Testing (Functional Audit)

Securing the permit requires a successful physical "Cold & Hot" functional test witnessed by a BOMBA officer:

  1. Smoke Injection Test: Smoke is introduced into the return air stream to verify that the sensors trigger the Motorized Fire Dampers and shut down the fan within the regulated timeframe.

  2. Fire Compartmentation Audit: Verification that the AHU plant room is a sealed "fire cell" with a minimum 2-hour fire rating, including fire-rated doors and intumescent seals around pipe penetrations.

  3. Override Manual Control: Validation of the "Fireman’s Switch" located at the Fire Control Room, allowing manual override of the AHU system.


4. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU installation safe enough to pass a BOMBA audit? Contact EKG (Malaysia) SDN BHD today for a specialized BOMBA Certified AHU Installation assessment.

Are you applying for a Safety Permit for a new commercial development or as part of a fire safety upgrade for an existing facility?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD