Multi-mode, multi-parameter measurement for broader applications
Equipped with plant mode,accurately detect PPFD
1,000,000Lux ultra-large range design
High precision, pass authoritative metrology inspection
LS330 spectral Illuminance Meter is a versatile instrument designed with a spectral sensor. It is used for measuring illuminance, UV index, flicker frequency, standard deviation of color matching (SDCM), color rendering index (CRI), correlated color temperature (CCT), blue light hazard ratio, temperature, and humidity in various scenarios such as lamps and lanterns lighting, outdoor lighting, greenhouse lighting, and stage lighting. The instrument also can display the spectral curve, which helps identify the type of lighting fixture.The instrument also has a plant illumination mode, which is specially designed for plant growth environments. It can accurately measurephotosynthetic photon flux density(PPFD), PPFD (Blue), PPFD (Green), PPFD (Red), Yield Photon Flux Density (YPFD), chlorophyll-a, and chlorophyll-b, helping users understand and optimize light management during the planting process and improve plant growth efficiency. It is suitable for home gardening, plant factories, greenhouses, agricultural research, plant lighting, and other fields.
| Parameters | Value |
|---|---|
| Illuminance Wavelength Range | 400nm ~ 700nm |
| Illuminance Wavelength Interval | 10nm |
| Illuminance Measurement Range | 0 ~ 1000000Lux |
| Illuminance Resolution | 0.1Lux |
| Illuminance Measurement Accuracy | ≤±(3%H + 2 Lux) (H is the standard value, calibrated under CIE standard A light source) |
| Illuminance Unit Options | Lux (default), FC |
| Correlated Color Temperature Measurement Range | 1000 ~ 100000K |
| UV Index Measurement Range | 0.0 ~ 15.0 |
| Flicker Frequency Measurement Range | 10 ~ 500HZ |
| Temperature Measurement Accuracy | ±0.5℃ |
| Humidity Measurement Accuracy | ±4%RH |
| PPFD measurement range | 0 – 10000 μmol/m²/s |
| PPFD measurement accuracy | ≤±(5%H+0.5 μmol/m²/s) |
| PPFD (Blue) measurement range | 0 – 5000 μmol/m²/s |
| PPFD (Blue) measurement accuracy | ≤±(10%H+0.5 μmol/m²/s) |
| PPFD (Green) measurement range | 0 – 5000 μmol/m²/s |
| PPFD (Green) measurement accuracy | ≤±(10%H+0.5 μmol /m²/s) |
| PPFD (Red) measurement range | 0 – 5000 μmol/m²/s |
| PPFD (Red) measurement accuracy | ≤±(10%H+0.5 μmol /m²/s) |
| YPFD measurement range | 0 – 10000 μmol/m²/s |
| YPFD measurement accuracy | ≤±(5%H+0.5 μmol /m²/s) |
| Chlorophyll-a measurement range | 0 – 10000μW/cm² |
| Chlorophyll-a measurement accuracy | 1.≤±(10%H+0.5μW/cm²) |
| Chlorophyll-b measurement range | 0 – 10000μW/cm² |
| Chlorophyll-b measurement accuracy | ≤±(10%H+0.5μW/cm²) |
| Response Time | <0.7s |
| Test Aperture Diameter | Φ21mm |
| Size | Length 188.5mm Width 75.2mm Height 30.3mm |
| Weight | About 232g (including batteries) |
| Display | 240*160 Dot Matrix LCD |
| Power Supply | 2 AA Alkaline Batteries |
| Operating Environment | Temperature 0 ~ 40℃, Humidity <85%RH |
In normal mode, the instrument measures parameters like illumination, CCT, flicker frequency, UV index, SDCM, CRI, temperature, and humidity to evaluate lighting characteristics. In plant mode, it accurately measures PPFD, YPFD, chlorophyll-a, and chlorophyll-b to optimize plant lighting for better quality and yield.
The instrument offers both normal and plant illumination modes, meeting diverse measurement needs. It handles both everyday lighting detection and plant growth parameters (e.g., PPFD, chlorophyll content), helping users optimize lighting in various scenarios.
The instrument has a spectral curve measurement function, which can view the light intensity and distribution at different wavelengths, identify whether the light source has spectral missing and detect whether it has blue light protection.
Ultra-large range design, range up to 1 million Lux, both strong and dim light can be measured accurately.
The instrument measures correlated color temperature, aiding lighting manufacturers in fixture development and lighting design.
The blue light hazard ratio can be displayed to objectively evaluate the blue light hazard of the lighting source.
(The blue light hazard ratio is the ratio of the blue light hazard to the corresponding radiation amount. The larger the ratio, the greater the proportion of blue light.)
The instrument can accurately measure photosynthetic photon flux density (PPFD), yield photon flux density (YPFD) and chlorophyll content, providing comprehensive data support to help optimize plant light intensity, distribution and health status, and improve growth and yield.
Malaysia