LS125 UV Light Meter +UVA-X0 Probe

Spectral response range: 315nm-400nm, λp = 365nm

Suitable for 365nm high-pressure mercury lamps
Power measuring range: 0 - 2000mW/cm²
Statistics function, it can measure energy values and power values at the same time

 

The LS125 UV light meter is a smart host that can support 12 different types of probes. Its main function is data display. The UVA-X0 probe is one of the 12 probes equipped with the LS125 host. The probe's spectral response range is 315nm-400nm, calibrated at 365nm. The UV light meter is suitable for detecting the intensity and energy of high pressure mercury lamps.

Parameters

Parameters UVA-X0 Probe
Spectral Response 315nm-400nm, λp = 365nm
Power Measuring Range 0 - 2000mW / cm²
Resolution 0.1mW / cm²
Energy Measuring Range 0-9999999mJ/cm²
Record Time 0-99999s
Measuring Accuracy(H is the Standard Value) H<5mW/cm²:±0.5mW/cm²
H>=5mW/cm²:±10%H
Sampling Speed 2048 times/second
Unit mW / cm² (default), W / m²
Test Hole Diameter Φ=10mm
Probe Size 39mm * 32mm * 15mm(L*W*H)
Packing Box Dimension 24 * 6 * 5 cm (L * W * H)
 
 

If you want to know about other types of probes supported by the LS125 UV light meter host, please click "LS125 Multi-Probe UV light meter Host" for details.

Application

 
 
 
 

Features

Specialized in testing high-pressure mercury lamps, Measure accurately

Suitable for intensity and energy test of 365nm high pressure mercury lamp. Energy and power values can be measured simultaneously. The measurement accuracy is guaranteed by the Chinese National Metrology Institute

 

Intelligent statistics function

The LS125 UV radiometer + UVA-X0 probe has rich statistical functions, and the real-time power value, maximum value, minimum value, average value, measurement time and energy value are displayed at the same time

 


Advanced digital probe technology

The probe adopts advanced digital probe technology. All data collection and processing are completed inside the probe and data transmission through digital signals with stronger anti-interference ability can ensure more stable test data

 

2048 times/sec acquisition speed

With high-speed acquisition of 2048 times per second, the test data is more accurate

 

Units can switch freely

Two measurement units can be switched, namely mW/cm², W/m². Data conversion between different units does not require manual calculation

 

 