Application
		
			In the ammonia reactor, nitrogen reacts with hydrogen to form ammonia. The temperature in the reactor can be anywhere up to 500 °C at pressures of 200 bar. To monitor the system pressure, the measurement itself does not take place in the interior of the reactor, but in the cooler inlet pipe of the reactor.
		
			
				Your benefit
			
				
					
						Reliable
					
						Special sealing concept prevents diffusion by the ammonia
				 
				
					
						Cost effective
					
						Maintenance-free operation even at high temperatures and pressures
				 
				
					
						User friendly
					
						Simple installation and commissioning
				 
			 
		 
		
		
			
				Recommended products
			
				
					
						
							
							
								
									VEGABAR 81
								
									
										Pressure transmitter for measuring pressure at reactor inlet
									
										- 
											Reliable measurement at high temperatures and pressures
- 
											Special sealing concept prevents ammonia diffusion when handling aggressive media
- 
											Long service life through use of chemically resistant materials
 
								
									
										
											Measuring range - Distance
										
									 
									
										
											Measuring range - Pressure