The OPTITEMP TRA-C61 is a compact resistance sensor (RTD) with optional integrated transmitter for hygienic use in limited space. The temperature sensor is particularly designed for food & beverage applications. This includes the temperature measurement of beverages, dairy products or pasty food. The sensor is therefore made of stainless steel (1.4404 / 316L) with an industry-specific surface finish of the thermowell of Ra ≤0.8 μm. It complies with FDA and EC1935/2004 regulations. Its G1⁄2 thread for hygienic adapters leaves freedom of choice for the process connections. The compact RTD sensor is available with VARIVENT®, dairy screw (DIN 11851), SMS 1145 as well as different weld-in sleeves.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
Depending on selected device configuration
| Product type | Temperature sensor |
| Product family name | OPTITEMP |
| Product positioning | For hygienic applications |
| Measurement variables | Temperature |
| Measurement principle | Resistance (RTD) |
| Measured media | Liquids, Gases, Solids |
| Assembly with thermowell | No |
| Sensor mounting | Hygienic fitting |
| Measuring insert replaceable | No |
| Measuring insert type | Non-replaceable RTD |
| RTD element type | 1 x Pt100 |
| RTD configuration | 4-wire |
| Tolerance class (according to DIN EN 60751) | A, B |
| Temperature sensor connection type option | Built-in transmitter |
| Sheath diameters | Ø6/3 mm / 0.24/0.12 |
| Sheath dimensions |
|
| Mounting point | Pipe, Tank |
| Measuring point | Pipe, Tank |
| Process temperature |
-50…+200°C / |
| Thread connections |
G½ for hygienic adapters |
| Hygienic adapters |
Varivent®: N Ferrule with collar (DIN 11851): DN25, DN40, DN50 Collar ferrule (DIN 11864-1A): DN40, DN50 Collar ferrule (SMS 1147): 51 mm Straight weld-in sleeve Spherical weld-in sleeve Weld-in sleeve with shoulder Collared weld-in sleeve |
| Certificates/Approvals Hygienic | FDA, EHEDG, EC 1935/2004 |
| Ingress protection | IP66/67, IP69 |
| Analogue outputs | 4…20 mA |