General specifications |
|
Switching function |
Normally open (NO) |
|
Output type |
Two-wire |
|
Rated operating distance |
10 mm |
|
Installation |
flush |
|
Output polarity |
DC |
|
Assured operating distance |
0 ... 8.1 mm |
|
Actual operating distance |
9 ... 11 mm typ. |
|
Reduction factor rAl |
0.3 |
|
Reduction factor rCu |
0.25 |
|
Reduction factor r304 |
0.7 |
|
Output type |
2-wire |
|
Nominal ratings |
|
Operating voltage |
5 ... 60 V |
|
Switching frequency |
0 ... 150 Hz |
|
Hysteresis |
1 ... 10 % typ. 5 % |
|
Reverse polarity protection |
reverse polarity tolerant |
|
Short-circuit protection |
pulsing |
|
Voltage drop |
≤ 5 V |
|
Operating current |
2 ... 100 mA |
|
Lowest operating current |
2 mA |
|
Off-state current |
0 ... 0.5 mA typ. |
|
Time delay before availability |
≤ |
|
Switching state indicator |
all direction LED, yellow |
|
Functional safety related parameters |
|
MTTFd |
1710 a |
|
Mission Time (TM) |
20 a |
|
Diagnostic Coverage (DC) |
0 % |
|
Compliance with standards and directives |
|
Standard conformity |
|
|
|
Standards |
EN IEC 60947-5-2 |
|
Approvals and certificates |
|
UL approval |
cULus Listed, General Purpose |
|
CCC approval |
Certified by China Compulsory Certification (CCC) |
|
Ambient conditions |
|
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
|
Mechanical specifications |
|
Connection type |
cable |
|
Housing material |
brass, nickel-plated |
|
Sensing face |
PBT |
|
Degree of protection |
IP67 |
|
Cable |
|
|
|
Wire end ferrules |
yes |
|
|
Cable diameter |
4.8 mm ± 0.2 mm |
|
|
Bending radius |
> 10 x cable diameter |
|
|
Material |
PVC |
|
|
Color |
grey |
|
|
Number of cores |
2 |
|
|
Core cross section |
0.34 mm2 |
|
|
Length |
2 m |
|
Dimensions |
|
|
|
Length |
40 mm |
|
|
Diameter |
30 mm |