Piezoresistive working principle
Stainless steel housing (1.4305)
Optional 316L or titanium housing
Different models between 100 mBar and 600 Bar
Analog 4-20mA / 0-10V and CANopen output options
±0.5% F.S or ± 0.3% F.S accuracy
IP65 or IP67 protection class
Compact construction
| Marka | Atek |
| Measuring range | Diffrent models from 0…100mbar to 0…600Bar r |
| Different vacuum models from 0… -100mbar to 0…-1Bar | |
| Working Principle | Piezoresistive |
| Maximum Pressure Strength | 300%F.S. ≤700mbar, 200%F.S. <250Bar, 150%F.S ≥250Bar |
| *Can be 3 or 5 times. | |
| Oring – Sealing | Standard NBR, optional FKM(Viton) or EPDM |
| Supply Voltage | 4-20 mA: 8 … 32 VDC |
| 0-20 mA: 12 … 30 VDC | |
| 0-10 V: 12 … 30 VDC | |
| Ratiometric: 5 VDC | |
| CANopen: 8…26 VDC | |
| Current Consumption | 30mA max. |
| Output Signal | 4…20mA (2-wire), 0…20mA (3-wire) |
| 0…10VDC, 1…6VDC , 0…5VDC , Ratiometric | |
| CANopen | |
| Accuracy | ±%0,5 F.S @25ᵒC |
| ±%0,3 F.S @25ᵒC | |
| Response Time | 25ms (standard) … nominal pressure |
| 1ms, 5ms, 125ms (optional) | |
| Operating Temperature | -40°C…+85°C |
| Body Material | Stainless steel body – 1.4305 (AISI303) |
| Optional stainless 316L or Titanium | |
| Electrical Connection | Socker models DIN43650-A , DIN46350-C , M12 , Packard or |
| PVC cable 3 x 0.14mm2 | |
| Protection Classı | IP65 or IP67 |
| **If M12 plug-in models use a press-pressed plug cable | |
| Mounting / Tightening | 15 … 20 Nm |
Malaysia