Features:
Lineup of Linear Motors to Achieve Higher Speed and Higher Precision
| Item | Specifications | ||
| Ambient operating temperature and operating humidity | 0 to 55°C, 85% max. (with no condensation) | ||
| Storage ambient temperature and humidity | -20 to 65°C, 85% max. (with no condensation) | ||
| Operating and storage atmosphere | No corrosive gases | ||
| Vibration resistance | 10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be run continuously at a resonance point) | ||
| Insulation resistance | Between power supply terminals/power terminals and FG terminal: 0.5 MW min. (at 500 VDC) | ||
| Dielectric strength | Between power supply/power line terminals and FG terminal: 1,500 VAC for 1 min at 50/60 Hz | ||
| Protective structure | Built into panel | ||
| International standard | EU Directives and UK legislation |
EMC | EN 55011, EN 61000-6-2, IEC 61800-3 |
| Low Voltage | EN 61800-5-1 | ||
| Machinery | EN954-1 (Cat.3), EN ISO 13849-1: 2008 (Category 3) (PLc,d), ISO 13849-1: 2006 (Category 3) (PLc,d), EN61508 (SIL2), EN62061 (SIL2), EN61800-5-2 (STO), IEC61326-3-1 (SIL2) |
||
| UL standards | UL 508C | ||
| CSA standards | CSA C22.2 No. 14 | ||
| Korean Radio Regulations (KC) | Certified | ||
Malaysia