| Sensing head size | 5.5 mm x 5.5 mm x 19 mm | 
|---|---|
| Type | Square type, Unshielded | 
| Power source | DC Three-wires models | 
| Sensing distance | 1.6 mm ±15% | 
| Setting distance | 0 to 1.2 mm | 
| Differential distance | 10% max. of sensing distance | 
| Sensing object | Ferrous metal (Sensitivity lowers with non-ferrous metals.) | 
| Standard sensing object | Iron 12 x 12 x 1 mm | 
| Response frequency | 1 kHz (Average value) | 
| Power supply voltage | 12 to 24 VDC ripple (p-p) 10% max. | 
| Operating voltage range | 10 to 30 VDC | 
| Current consumption | at 24 VDC, no load: 13 mA max. | 
| Control output (Output type) | NPN open collector | 
| Control output (Switching capacity) | 50 mA max. (30 VDC max.) | 
| Control output (Residual voltage) | 1 V max. (Load current 50 mA with cable length of 1 m) | 
| Indicator | Operation indicator (orange) | 
| Operation mode | NO | 
| Protective circuit | Power supply reverse polarity protection Surge suppressor  | 
		
| Ambient temperature (Operating) | -25 to 70 ℃ | 
| Ambient temperature (Storage) | -40 to 85 ℃ | 
| Ambient humidity (Operating) | 35 to 90 % | 
| Ambient humidity (Storage) | 35 to 95 % | 
| Temperature influence | ±15% max. of sensing distance at 23 ℃ in the temperature range of −25 to 70 ℃ | 
| Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range | 
| Insulation resistance | Between charged parts and the case: 50 MΩ min. at 500 VDC | 
| Dielectric strength | Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min | 
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h | 
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | 
| Degree of protection | IEC: IP67 | 
| Connection method | Pre-wired models (1 m) | 
| Weight | Package: Approx. 10 g | 
| Material | Case: Polyarylate | 
| Accessories | Mounting Bracket | 
Malaysia