| Measuring range - Distance | 120 m |
| Process temperature | -196 ... 450 °C |
| Process pressure | -1 ... 160 bar |
| Accuracy | ± 1 mm |
| Frequency |
-6 GHz
-26 GHz
-80 GHz
|
| Beam angle | ≥ 3° |
| Materials, wetted parts |
-PTFE
-PVDF
-316L
-PP
-PEEK
|
| Threaded connection | ≥ G¾, ≥ ¾ NPT |
| Flange connection | ≥ DN20, ≥ ¾'' |
| Hygenic fittings |
-Clamp ≥ 1½'' - DIN32676, ISO2852
-Slotted nut ≥ 2'', DN50 - DIN 11851
-Varivent ≥ DN25
-hygienic fitting with tension flange DN32
-hygienic fitting F40 with compression nut
-Hygienic screw connections ≥ DN50 tube ø53 DIN11864-1-A
-Hygienice flange connection ≥ DN50 DIN11864-2
-Hygienic clamp connection ≥ DN50 pipe Ø53 DIN11864-3-A
-DRD connection ø 65 mm
-SMS 1145 DN51
|
| Seal material |
-EPDM
-FKM
-FFKM
-graphit and ceramic
-PTFE
|
| Housing material |
-Plastic
-Aluminium
-Stainless steel (precision casting)
-Stainless steel (electropolished)
|
| Protection rating |
-IP66/IP68 (0,2 bar)
-IP66/IP67
-IP66/IP68 (1 bar)
-IP69K
|
| Ambient temperature | -40 ... 80 °C |
| Scope |
-ATEX / Europe
-CSA / Canada
-FM / USA
-EAC (GOST) / Belarus
-EAC (GOST) / Kazakhstan
-EAC (GOST) / Russia
-IEC / worldwide
-KOSHA / Korea
-NEPSI / China
-UKR Sepro / Ukraine
-IEC / Australia
-INMETRO / Brazil
-CCOE / India
-CSA / USA and Canada
-TIIS / Japan
|
| Explosion protection |
-Intrinsic safety ''i''
-Flameproof enclosure ''d''
-Dust explosion protection through housing ''t''
|
| Foodstuffs/Pharma | Foodstuffs/Pharma |
| Ship approval | Ship approval |
| Overfill protection |
-WHG
-VLAREM II
|
| SIL qualification | SIL qualification |
| Adjustment |
-PLICSCOM
-PC, PACTware and DTM
-HART-Communicator
-Software (e. g. AMS™, PDM)
-Bluetooth
|
| Indication |
-Display/adjustment module PLICSCOM
-VEGADIS 81
-VEGADIS 82
|
Malaysia