DESCRIPTION & FEATURES:
| Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc Optional 3-wire: 0-20 mA / Vs = 14-30 Vdc 0-10 V / Vs = 14-36 Vdc |
| Accuracy |
±0.35% FSO Optional nominal pressure ≥ 5 psi: <±0.25% FSO BFSL All nominal pressure: <±0.1% FSO BFSL |
| Permissible Load |
Current 2-wire: Rmax = [(Vs – Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm |
| Influence Effects |
Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| Long-term Stability | <±0.1% FSO/yr |
| Response Time | ≤10ms* |
| Permissible Temperatures |
Medium: 14°F to 158°F (-10°C to 70°C) Storage: -13°F to 158°F (-25°C to 70°C) |
| Reverse Polarity Protection | No damage. No function. |
| Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
| Electrical Connection | Cable with sheath material**: PVC grey, PUR black, FEP black, others available |
| Pollution Degree | 4, electrical equipment for outdoor use |
| Housing | 316L SS |
| Seals | FKM, others available |
| Diaphragm | 316L SS |
| Weight | 200 g (without cable) |
| Current Consumption |
Current: 25 mA max Voltage: 7 mA max |
| Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |
| Enclosure Rating | NEMA 6P / IP68 |