APPLICATIONS:
DESCRIPTION & FEATURES:
| Output Signal | Standard 2-wire: 4-20 mA / Vs = 12-36 Vdc |
| Accuracy |
<±0.35% FSO BFSL Optional nominal pressure > 5 psi: <±0.25% FSO BFSL |
| Permissible Load | Rmax = [(Vs – Vs min) / 0.02] Ohm |
| Influence Effects |
Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| Long-term Stability | <±0.1% FSO/yr |
| Response Time | <10 ms |
| Permissible Temperatures |
Medium: 14°F to 158°F (-10°C to 70°C) Storage: -13°F to 158°F (-25°C to 70°C) |
| Reverse Polarity Protection | No damage. No function. |
| Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
| Electrical Connection | Cable with sheath material*: PVC grey, PUR black, FEP black |
| Housing | 316Ti SS |
| Seals | FKM / EPDM |
| Diaphragm | 316L SS |
| Weight | 100 g (without cable) |
| Current Consumption | 25 mA max |
| Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |
| Enclosure Rating | NEMA 6P / IP68 |