Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 900W
Slots: 6
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,34V,48V,±5,±12,±15,±24,5V/5V,5V/12V,5V/24V
AC(1) □(2) - □(3) □(4) □(5) □(6) □(7) □(8) - □□(9) - □□(10)
(1) Abbreviation type name of ACE series| Contents | Specifications | ||
|---|---|---|---|
| Input Voltage | AC85 - 264V 1Φ / DC120 - 350V * | ||
| Output | Number of Slot | 6 | |
| Total Output power | AC90 - 150V | 800W (Peak 1kW) | |
| AC170 - 264V | 900W (Peak 1kW) | ||
| Operating Temperature/Humidity | -20 to +70℃, 20 - 90%RH (Non condensing) | ||
| Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL (CSA60950-1) , EN60950-1, EN50178, EN62368-1 Complies with DEN-AN (At only AC input) UL60601-1, EN60601-1 (At only AC input) (Refer to instruction manual 7) |
|
| Conducted Noise | Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B | ||
| High Attenuation | Complies with IEC61000-3-2 * | ||
| Others | Dimensions (WxHxD) | 177.5x63.5x254mm [6.99x2.5x10 inches] | |
| Weight | 3.0kg max | ||
| Cooling Method | Forced cooling (built-in) | ||
| Warranty Period | 3-year | ||
| Contents | Specifications | |||||
|---|---|---|---|---|---|---|
| Module Code | L | M | N | P | R | |
| Number of Slots Used | 1 | 1 | 1 | 1 | 1 | |
| Output | Wattage | 33W | 50W | 60W | 60W | 60W |
| Voltage/Current | 3.3V 10A | 5V 10A | 12V 5A | 15V 4A | 24V 2.5A | |
| Adjustable Voltage Range | 2.60 - 3.60V | 4.00 - 5.50V | 9.00 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
|
Protection Circuit And Others |
Overcurrent Protection |
Works over 105%min of rated current. Automatic recovery.
|
||||
| Overvoltage Protection | 4.00 - 5.25V | Works at 115 - 140% of rated voltage | ||||
| Remote ON/OFF |
Available
|
|||||
| Remote Sensing |
-
|
|||||
| Others |
-
|
|||||
| Contents | Specifications | ||||
|---|---|---|---|---|---|
| Module Code | Y | W | Z | 9 | |
| Number of Slots Used | 1 | 1 | 1 | 1 | |
| Output | Wattage* | 50W | 76.8W | 75W | 76.8W |
| Voltage | ±5V | ±12V | ±15V | ±24V | |
| Current1* | 3A | 3.2A | 2.5A | 1.6A | |
| Current2* | 7A | 4.2A | 3.5A | 2.5A | |
| Peak Current* | - | 5A | 4A | - | |
| Adjustable Voltage Range | 4.99 - 6.00V | 9.60 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
|
Protection Circuit And Others |
Overcurrent Protection |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery.
|
|||
| Overvoltage Protection | 6.90 - 8.40V | 13.8 - 16.8V | 17.25 - 21.0V | 27.6 - 33.6V | |
| Remote ON/OFF |
Available
|
||||
| Remote Sensing |
-
|
||||
| Others |
-
|
||||
| Contents | Specifications | ||
|---|---|---|---|
| Module Code | Q | V | |
| Number of Slots Used | 1 | 1 | |
| Output | Wattage* | 153.6W | 165W |
| Voltage | ±12V | ±15V | |
| Current1* | 6.4A | 5.5A | |
| Current2* | 8A | 7A | |
| Peak Current* | 10A | 8A | |
| Adjustable Voltage Range | 9.60 - 13.2V | 13.2 - 16.5V | |
| Protection Circuit And Others | Overcurrent Protection |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery.
|
|
| Overvoltage Protection | Works at 115 - 140% of rated voltage | ||
| Remote ON/OFF |
Available
|
||
| Remote Sensing |
-
|
||
| Others |
-
|
||
| Contents | Specifications | ||||||
|---|---|---|---|---|---|---|---|
| Module Code | S | T | U | ||||
| Number of Slots Used | 1 | 1 | 1 | ||||
| Output | Wattage | 75W | 100.4W | 100.4W | |||
| Voltage/Current |
V1: 5V 10A |
V2: 5V 5A |
V1: 5V 10A |
V2: 12V 4.2A |
V1: 5V 10A |
V2: 24V 2.1A |
|
| Adjustable Voltage Range | 4.99 - 5.50V | 3.00 - 5.50V | 4.99 - 5.50V | 7.50 - 13.2V | 4.99 - 5.50V | 15.0 - 26.4V | |
| Protection Circuit And Others | Overcurrent Protection |
Works over 105%min of rated current. Automatic recovery.
|
|||||
| Overvoltage Protection |
Works at 115 - 140% of rated voltage
|
||||||
| Remote ON/OFF |
Available
|
||||||
| Remote Sensing |
-
|
||||||
| Others |
-
|
||||||