Measurement ranges |
30A, 300A and 3000A, switch selectable |
|
Output sensitivity |
100mV/A on the 30A range |
|
10mV/A on the 300A range |
|
1mV/A on the 3000A range |
|
Output coupling |
AC coupled. |
|
Accuracy (50/60Hz) |
± 1% F.S. @ 23 ± 5°C (50/60Hz) |
|
Frequency range |
45 to 400 Hz. |
|
Max conductor size |
Round: (177mm (7''), Oval: 216mm (8.5'') |
|
Phase error (50/60Hz) |
< ± 1° |
|
Minimum load |
100 K ohm for specified accuracy |
|
Linearity |
±0.2% of reading from 10% to 100% of range |
|
Phase error |
<±1.5° (50/60Hz) |
|
Conductor position sensitivity |
± 2% F.S (conductor should be >25mm (1'') from the probe latch). |
|
Enclosure material |
UL 94-V0 rated |
|
Safety |
IEC 1010, Category III 600V |
|
Power Supply |
8V± 1V (supplied from meter) |
|
Operating Temperature |
0°C to 50°C (32°F to 122°F) |
|
Operating Humidity |
Less than 80% RH |
|
Dimension |
|
Circuit box: |
105 x 56.5 x 33 mm. (4.1 X 2.2 X 1.3'') |
|
Flexible probe: |
600mm (23.6'') (length), 14.5mm 0.57'' (diameter) |
|
Cable length : |
3.4 meters (11.2 feet) |
|
DC plug size : |
5.5 mm x 2.5 mm DIA. |
|
Weight |
480 g (1.06 LB) |