Detection principle |
Catalytic, electro-chemical, NDIR, or PID |
|
Gas sampling |
Diffusion |
|
Measurement range |
0 ~ 100%LEL, 0 ~ 10,000ppm, 0 ~ 100%VOL |
|
Target gas |
Combustible or toxic - see the table of target gases |
|
Response time |
within 20 seconds, 90%/full scale |
|
Accuracy |
≤2% /full scale |
|
Calibration |
One-touch auto calibration |
|
Sensor displacement |
Zero calibration: ≤±1%LEL/6 month
span calibration: ≤±1%LEL/6 month |
|
Self diagnosis |
Display sensor failure on built-in FND(S.Er), 2mA output |
|
Input power |
DC 20 ~ 30V |
|
Output signal |
4 ~ 20mA/full scale – up to 2.5km transmission |
|
Operating temp. & humidity |
-20℃~ 50℃, 5 ~ 95% RH (Non-Condensing) |
|
Signal cable |
CVVS & CVVSB 1.25sq x 3 Wire - Shield Type |
|
Conduit tube |
1/2' or 3/4' PF, NPT |
|
Installation type |
Wall or Pipe Mounting |
|
Casing material |
Cast aluminum alloy |
|
Explosion-proof approval |
Ex d IIC T5 |