AC A |
200/600A (True RMS)
±1.5%rdg±4dgt [50/60Hz] (CF<3)
±2%rdg±5dgt [40Hz - 1kHz] (Sine wave) |
|
AC V |
200/600V (True RMS) (CF<3)
±1.5%rdg±4dgt [50/60Hz]
±2%rdg±5dgt [40Hz - 1kHz] |
|
Ω |
200Ω
±1.2%rdg±4dgt |
|
Continuity buzzer |
buzzer sounds below 30±20Ω |
|
Conductor size |
Ø33mm max. |
|
Frequency response |
40Hz - 1kHz |
|
Safety Standard |
IEC 61010-1 CAT III 600V Pollution Degree 2
IEC 61010-2-031 |
|
Power source |
6F22 (9V) × 1 |
|
Dimensions |
208(L) × 91(W) × 40(D)mm |
|
Weight |
400g approx. |
|
Included Accessories |
7066A (Test leads)
9079 (Carrying case)
6F22 × 1
Instruction Manual |