| Measuring elements | NDIR Infrared CO2 Sensor SENSEAIR |
| Response time (flowing air) | 2 minutes by 90% |
| accuracy | <±5%FS |
| Measurement range | CO2: 0~2000ppm (customizable to user requirements) |
| Output signal | 0-5VDC |
| Pressure error | CO2: 1.6% of the measured value/kPa |
| Service life | 5 years (non-corrosive environment) |
| Work environment | Temperature: 0~50℃; Humidity: 0~85%RH (non-condensing) |
| Storage temperature | Temperature: -20~60℃; Humidity: 20~80%RH |
| preheating time | It is recommended to spend at least 15 minutes. |
| Power supply | 24VDC |
| High power | Less than 2.5W |
| Casing size | 106×106×32mm |
| Installation method | Wall-mounted/Ceiling-mounted |
| weight | Approximately 200g |
| Shell material | ABS |
Malaysia