The meters can be used to measure DC & AC voltage, DC & AC current, resistance, capacitor, frequency, duty cycle, temperature, transistor hFE, Non Contact AC Voltage (NCV) detection, positive diode voltage fall and audible continuity.
Product features:
The meters can be used to measure DC & AC voltage, DC & AC current, resistance, capacitor, frequency, duty cycle, temperature, transistor hFE, Non Contact AC Voltage (NCV) detection, positive diode voltage fall and audible continuity.
Product Specification
1 Max Voltage between input terminal and Earth Ground: CAT Ⅲ 1000V
2 Over-range Indication: display “OL” for the significant digit.
3 Automatic display of negative polarity “
” .
4 Low Battery Indication: “
” displayed.
5 Max LCD display: 6000 counts digit.
6 Auto range & Manual range control
7 Auto Power Off: When measurement exceeds 15 minutes without switching mode and pressing key, the meter will switch to standby mode. Press any key to exit standby mode. When restart the system, press and hold SELECT/HOLD key to disable auto power off.
8 Mechanical blocking system & Function switch indicator lamp
9 Auto LCD backlight
10 Fuse protection: 800mA/250V Fast Fuse, 20A/250V Fast Fuse
11 Power supply: 9V battery (6F22 or NEDA 1604)
12 Operating Temp.: 0℃ to 40℃ (relative humidity <85%)
13 Storage Temp.: -10℃ to 50℃ (relative humidity <85%)
14 Guaranteed precision Temp.: 23±5℃ (relative humidity <70%)
15 Dimension: 195x88x40mm
16 Weight: approx. 350g (including battery)

Malaysia