Tip: 19mm. Probe cover is removable.
| range | resolution | Accuracy | |
|---|---|---|---|
| ACV | 6.000m V | 1m V | ±(1.5 %rdg + 5 dgt) *0.1 Vrms~ |
| 60.00 V | 10 V | ||
| 600.0 V | 100 V | ||
| DCV | 600.0mV | 0.1mV | ±(0.8%rdg + 5dgt) |
| 6.600 V | 0.001 V | ±(1.5%rdg + 2dgt) | |
| 66.00 V | 0.01 V | ||
| 600.0 V | 0.1 V | ±(1.5%rdg + 5dgt) | |
| ACA | 100.0 A | 0.1 A | ±(3.0%rdg + 5dgt) |
| DCA | 100.0 A | 0.1 A | ±(3.0%rdg + 5dgt) |
| Ω | 660.0 Ω | 0.1 Ω | ±(1.0%rdg + 4dgt) |
| 6.000 kΩ | 1 ohm | ±(1.5%rdg + 2dgt) | |
| 60.00 kΩ | 10 ohms | ||
| 600.0 kΩ | 100 ohms | ||
| 6.000 MΩ | 1 kΩ | ±(2.0%rdg + 5dgt) | |
| 60.00M Ω | 10 kΩ | ±(3.0%rdg + 8dgt) | |
| frequency | 9.999 Hz | 0.001 Hz | ±(1.0 ±5 dgt) |
| 99.99 Hz | 0.01 Hz | ||
| 999.9 Hz | 0.1 Hz | ||
| 9.999 kHz | 0.001 kHz | ||
| 99.99 kHz | 0.01 kHz | ||
| 999.9 kHz | 0.1 kHz | ||
| Capacitance (CAP) |
9.999 nF | 0.001 nF | - |
| 99.99 nF | 0.01 nF | ±(4.5% + 20dgt) | |
| 999.9 nF | 0.1 nF | ±(3.0 ±5 dgt) | |
| 9.999 μF | 0.001 μF | ||
| 99.99 μF | 0.01 μF | ||
| 999.9 μF | 0.1 μF | - | |
| 9.999 mF | 0.001 mF | ||
| 99.99 mF | 0.01 mF | ||
| DUTY % |
20 to 80% | 0.1% | - |
| frequency Hz |
9.999 Hz | 0.001 Hz | ±(1.0% + 5 dgt) |
| 99.99 Hz | 0.01 Hz | ||
| 999.9 Hz | 0.1 Hz | ||
| 9.999 kHz | 0.001 kHz | ||
| 99.99 kHz | 0.01 kHz | ||
| 999.9 kHz | 0.1 kHz |
| Measurement range | Accuracy | ||
|---|---|---|---|
| frequency | alternating current | 50 to 1 kHz | ±(0.1% + 3 dgt) |
| AC voltage | 50 to 1 kHz | ±(0.1% + 3 dgt) |
| Continuity check | Buzzer threshold: approx. 50 Ω |
|---|---|
| Diode Check | Forward voltage: Approx. 0.4 to 0.9 V Reverse voltage: .OL displayed |
| Function | Maximum rated input value | Notes Ω |
|---|---|---|
| DCV/ACV | DC 600V /AC 600V | Buzzer when DC/AC exceeds 600V |
| DCA/ACA | DC 100A/AC 100A | - |
| Ω, CAP, diode check, continuity check | (Voltage input prohibited) | DC 250V / AC 250V withstand voltage |
| Hz, % | (Square wave 5Vp-p standard) | DC 250V / AC 250V withstand voltage |
| Detection method | True RMS |
|---|---|
| display | LCD, maximum display "6000", with bar graph (61 segments) |
| Range switching | Auto (Manual available) |
| polarity display | Automatic switching, only "-" displayed |
| Clamp maximum measurement conductor diameter | φ12mm |
| sampling | Approximately 3 times/second |
| Auto Power Off | Approximately 15 minutes (can be canceled) |
| Operating temperature and humidity | 0 to +40°C, 80% RH or less (no condensation) |
| Storage temperature and humidity | -10 to +60°C, 80% RH or less (no condensation) |
| size | Approx. W 81 x H 135 x D 30 mm |
| weight | Approximately 200 g (excluding batteries) |
| power supply | 2 x AAA batteries (sold separately) |
| accessories | Instruction manual (with warranty), 2 probe covers (pre-installed) |
| option | |
| proofreading | Possible |
| Compliance standards | IEC61010-1 compliant CAT III 300V, CAT II 600V |
| JAN | 4983621930030 |
Malaysia