| General information | |||
| Product type designation | CPU 416-2 | ||
| HW functional status | 04 | 01 | |
| Firmware version | V5.3 | V7.0 | |
| Product function | |||
| ● Isochronous mode | Yes; For PROFIBUS only | ||
| Engineering with | |||
| ● Programming package | STEP 7 V5.3 SP2 or higher with HW update | STEP 7 V5.4 or higher with HSP 261 | |
| CiR - Configuration in RUN | |||
| CiR synchronization time, basic load | 100 ms | ||
| CiR synchronization time, time per I/O byte | 10 µs | ||
| Supply voltage | |||
| Rated value (DC) | Power supply via system power supply | ||
| Input current | |||
| from backplane bus 5 V DC, typ. | 0.9 A | ||
| from backplane bus 5 V DC, max. | 1.1 A | ||
| from backplane bus 24 V DC, max. | 300 mA; 150 mA per DP interface | ||
| from interface 5 V DC, max. | 90 mA; At each DP interface | ||
| Power loss | |||
| Power loss, typ. | 4.5 W | ||
| Memory | |||
| Type of memory | RAM | ||
| Work memory | |||
| ● integrated | 5.6 Mbyte | 8 Mbyte | |
| ● integrated (for program) | 2.8 Mbyte | 4 Mbyte | |
| ● integrated (for data) | 2.8 Mbyte | 4 Mbyte | |
| ● expandable | No | ||
| Load memory | |||
| ● expandable FEPROM | Yes; with Memory Card (FLASH) | ||
| ● expandable FEPROM, max. | 64 Mbyte | ||
| ● integrated RAM, max. | 1 Mbyte | ||
| ● expandable RAM | Yes; with Memory Card (RAM) | ||
| ● expandable RAM, max. | 64 Mbyte | ||
| Backup | |||
| ● present | Yes | ||
| ● with battery | Yes; all data | ||
| ● without battery | No | ||
| Battery | |||
| Backup battery | |||
| ● Backup current, typ. | 125 µA; up to 40 °C | 180 µA; up to 40 °C | |
| ● Backup current, max. | 550 µA | 850 µA | |
| ● Backup time, max. | See reference manual, module data, Chapter 3.3 | Dealt with in the module data manual with the secondary conditions and the factors of influence | |
| ● Feeding of external backup voltage to CPU | 5 V DC to 15 V DC | ||
| CPU processing times | |||
| for bit operations, typ. | 30 ns | 12.5 ns | |
| for word operations, typ. | 30 ns | 12.5 ns | |
| for fixed point arithmetic, typ. | 30 ns | 12.5 ns | |
| for floating point arithmetic, typ. | 90 ns | 25 ns | |
| CPU-blocks | |||
| DB | |||
| ● Number, max. | 10 000; Number range: 1 to 16000 | ||
| ● Size, max. | 64 kbyte | ||
| FB | |||
| ● Number, max. | 5 000; Number range: 0 to 7999 | ||
| ● Size, max. | 64 kbyte | ||
| FC | |||
| ● Number, max. | 5 000; Number range: 0 to 7999 | ||
| ● Size, max. | 64 kbyte | ||
| OB | |||
| ● Number, max. | see instruction list | ||
| ● Size, max. | 64 kbyte | ||
| ● Number of free cycle OBs | 1; OB 1 | ||
| ● Number of time alarm OBs | 8; OB 10-17 | ||
| ● Number of delay alarm OBs | 4; OB 20-23 | ||
| ● Number of cyclic interrupt OBs | 9; OB 30-38 (shortest cycle that can be set = 500 µs) | ||
| ● Number of process alarm OBs | 8; OB 40-47 | ||
| ● Number of DPV1 alarm OBs | 3; OB 55-57 | ||
| ● Number of isochronous mode OBs | 4; OB 61-64 | ||
| ● Number of multicomputing OBs | 1; OB 60 | ||
| ● Number of background OBs | 1; OB 90 | ||
| ● Number of startup OBs | 3; OB 100-102 | ||
| ● Number of asynchronous error OBs | 9; OB 80-88 | ||
| ● Number of synchronous error OBs | 2; OB 121, 122 | ||
| Nesting depth | |||
| ● per priority class | 24 | ||
| ● additional within an error OB | 2 | ||
| Counters, timers and their retentivity | |||
| S7 counter | |||
| ● Number | 2 048 | ||
| Retentivity | |||
| — adjustable | Yes | ||
| — preset | Z 0 to Z 7 | ||
| Counting range | |||
| — lower limit | 0 | ||
| — upper limit | 999 | ||
| IEC counter | |||
| ● present | Yes | ||
| ● Type | SFB | ||
| ● Number | Unlimited (limited only by RAM capacity) | ||
| S7 times | |||
| ● Number | 2 048 | ||
| Retentivity | |||
| — adjustable | Yes | ||
| — preset | No times retentive | ||
| Time range | |||
| — lower limit | 10 ms | ||
| — upper limit | 9 990 s | ||
| IEC timer | |||
| ● present | Yes | ||
| ● Type | SFB | ||
| ● Number | Unlimited (limited only by RAM capacity) | ||
| Data areas and their retentivity | |||
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) | ||
| Flag | |||
| ● Size, max. | 16 kbyte; Size of bit memory address area | ||
| ● Retentivity available | Yes | ||
| ● Retentivity preset | MB 0 to MB 15 | ||
| ● Number of clock memories | 8; in 1 memory byte | ||
| Local data | |||
| ● adjustable, max. | 32 kbyte | ||
| ● preset | 16 kbyte | ||
| Address area | |||
| I/O address area | |||
| ● Inputs | 16 kbyte | ||
| ● Outputs | 16 kbyte | ||
| Process image | |||
| ● Inputs, adjustable | 16 kbyte | ||
| ● Outputs, adjustable | 16 kbyte | ||
| ● Inputs, default | 512 byte | ||
| ● Outputs, default | 512 byte | ||
| ● consistent data, max. | 244 byte | ||
| ● Access to consistent data in process image | Yes | ||
| Subprocess images | |||
| ● Number of subprocess images, max. | 15 | ||
| Digital channels | |||
| ● Inputs | 131 072 | ||
| — of which central | 131 072 | ||
| ● Outputs | 131 072 | ||
| — of which central | 131 072 | ||
| Analog channels | |||
| ● Inputs | 8 192 | ||
| — of which central | 8 192 | ||
| ● Outputs | 8 192 | ||
| — of which central | 8 192 | ||
| Hardware configuration | |||
| Integrated power supply | No | ||
| Number of expansion units, max. | 21 | ||
| connectable OPs | 63 | 95 | |
| Multicomputing | Yes; 4 CPUs max. (with UR1 or UR2) | ||
| Interface modules | |||
| ● Number of connectable IMs (total), max. | 6 | ||
| ● Number of connectable IM 460s, max. | 6 | ||
| ● Number of connectable IM 463s, max. | 4; IM 463-2 | ||
| Number of DP masters | |||
| ● integrated | 2 | ||
| ● via CP | 10; CP 443-5 Extended | ||
| ● via IM 467 | 4 | ||
| ● Mixed mode IM + CP permitted | No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode) | No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode | |
| ● via interface module | 0 | ||
| ● Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 | ||
| Number of IO Controllers | |||
| ● integrated | 0 | ||
| ● via CP | 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller | 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode | |
| Number of operable FMs and CPs (recommended) | |||
| ● FM | Limited by number of slots and number of connections | ||
| ● CP, PtP | CP 440: Limited by number of slots; CP 441: limited by number of connections | ||
| ● PROFIBUS and Ethernet CPs | 14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum | 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller | |
| Slots | |||
| ● required slots | 1 | ||
| Time of day | |||
| Clock | |||
| ● Hardware clock (real-time) | Yes | ||
| ● retentive and synchronizable | Yes | ||
| ● Resolution | 1 ms | ||
| ● Deviation per day (buffered), max. | 1.7 s; Power off | ||
| ● Deviation per day (unbuffered), max. | 8.6 s; For power On | ||
| Operating hours counter | |||
| ● Number | 16 | ||
| ● Number/Number range | 0 to 15 | ||
| ● Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours | ||
| ● Granularity | 1 h | ||
| ● retentive | Yes | ||
| Clock synchronization | |||
| ● supported | Yes | ||
| ● to MPI, master | Yes | ||
| ● on MPI, device | Yes | ||
| ● to DP, master | Yes | ||
| ● on DP, device | Yes | ||
| ● in AS, master | Yes | ||
| ● in AS, device | Yes | ||
| ● on Ethernet via NTP | No; Via CP | ||
| ● to IF 964 DP | No | ||
| Time difference in system when synchronizing via | |||
| ● MPI, max. | 200 ms | ||
| Interfaces | |||
| Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP | ||
| Number of RS 485 interfaces | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP | ||
| Optical interface | No | ||
| 1. Interface | |||
| Interface type | MPI/PROFIBUS DP | ||
| Isolated | Yes | ||
| Interface types | |||
| ● RS 485 | Yes | ||
| ● Output current of the interface, max. | 150 mA | ||
| Protocols | |||
| ● MPI | Yes | ||
| ● PROFIBUS DP master | Yes | ||
| ● PROFIBUS DP device | Yes | ||
| MPI | |||
| ● Number of connections | 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | ||
| ● Transmission rate, max. | 12 Mbit/s | ||
| Services | |||
| — PG/OP communication | Yes | ||
| — Routing | Yes | ||
| — Global data communication | Yes | ||
| — S7 basic communication | Yes | ||
| — S7 communication | Yes | ||
| — S7 communication, as client | Yes | ||
| — S7 communication, as server | Yes | ||
| PROFIBUS DP master | |||
| ● Number of connections, max. | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | ||
| ● Transmission rate, max. | 12 Mbit/s | ||
| ● max. number of DP devices | 32 | ||
| Services | |||
| — PG/OP communication | Yes | ||
| — Routing | Yes; S7 routing | ||
| — Global data communication | No | ||
| — S7 basic communication | Yes | ||
| — S7 communication | Yes | ||
| — S7 communication, as client | Yes | ||
| — S7 communication, as server | Yes | ||
| — Equidistance | Yes | ||
| — Isochronous mode | Yes | ||
| — SYNC/FREEZE | Yes | ||
| — activation/deactivation of DP devices | Yes | ||
| — Direct data exchange (slave-to-slave communication) | Yes | ||
| — DPV1 | Yes | ||
| Address area | |||
| — Inputs, max. | 2 kbyte | ||
| — Outputs, max. | 2 kbyte | ||
| User data per DP device | |||
| — user data per DP device, max. | 244 byte | ||
| — Inputs, max. | 244 byte | ||
| — Outputs, max. | 244 byte | ||
| — Slots, max. | 244 | ||
| — per slot, max. | 128 byte | ||
| 1st interface / PROFIBUS DP device / header | |||
| ● Number of connections | 32 | ||
| ● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | ||
| ● Transmission rate, max. | 12 Mbit/s | ||
| ● automatic baud rate search | No | ||
| ● Address area, max. | 32; Virtual slots | ||
| ● User data per address area, max. | 32 byte | ||
| — of which consistent, max. | 32 byte | ||
| Services | |||
| — PG/OP communication | Yes; with interface active | ||
| — Routing | Yes; with interface active | ||
| — Global data communication | No | ||
| — S7 basic communication | No | ||
| — S7 communication | Yes | ||
| — S7 communication, as client | Yes | ||
| — S7 communication, as server | Yes | ||
| — Direct data exchange (slave-to-slave communication) | No | ||
| — DPV1 | No | ||
| Transfer memory | |||
| — Inputs | 244 byte | ||
| — Outputs | 244 byte | ||
| 2. Interface | |||
| Interface type | PROFIBUS DP | ||
| Isolated | Yes | ||
| Interface types | |||
| ● RS 485 | Yes | ||
| ● Output current of the interface, max. | 150 mA | ||
| Protocols | |||
| ● PROFIBUS DP master | Yes | ||
| ● PROFIBUS DP device | Yes | ||
| PROFIBUS DP master | |||
| ● Number of connections, max. | 32 | ||
| ● Transmission rate, max. | 12 Mbit/s | ||
| ● max. number of DP devices | 125 | ||
| Services | |||
| — PG/OP communication | Yes | ||
| — Routing | Yes; S7 routing | ||
| — Global data communication | No | ||
| — S7 basic communication | Yes | ||
| — S7 communication | Yes | ||
| — S7 communication, as client | Yes | ||
| — S7 communication, as server | Yes | ||
| — Equidistance | Yes | ||
| — Isochronous mode | Yes | ||
| — SYNC/FREEZE | Yes | ||
| — activation/deactivation of DP devices | Yes | ||
| — Direct data exchange (slave-to-slave communication) | Yes | ||
| — DPV1 | Yes | ||
| Address area | |||
| — Inputs, max. | 8 kbyte | ||
| — Outputs, max. | 8 kbyte | ||
| User data per DP device | |||
| — user data per DP device, max. | 244 byte | ||
| — Inputs, max. | 244 byte | ||
| — Outputs, max. | 244 byte | ||
| — Slots, max. | 244 | ||
| — per slot, max. | 128 byte | ||
| 2nd interface / PROFIBUS DP device / header | |||
| ● Number of connections | 32 | ||
| ● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | ||
| ● Transmission rate, max. | 12 Mbit/s | ||
| ● Address area, max. | 32 | ||
| ● User data per address area, max. | 32 byte | ||
| — of which consistent, max. | 32 byte | ||
| Services | |||
| — Routing | Yes; with interface active | ||
| Transfer memory | |||
| — Inputs | 244 byte | ||
| — Outputs | 244 byte | ||
| Protocols | |||
| SIMATIC communication | |||
| ● S7 routing | Yes | ||
| Open IE communication | |||
| ● ISO-on-TCP (RFC1006) | Via CP 443-1 and loadable FB | ||
| — Data length, max. | 1 452 bytes via CP 443-1 Adv. | ||
| Web server | |||
| ● supported | No | ||
| Isochronous mode | |||
| Equidistance | Yes | ||
| Number of DP masters with isochronous mode | 2 | ||
| User data per isochronous slave, max. | 244 byte | ||
| shortest clock pulse | 1 ms; 0.5 ms without use of SFC 126, 127 | ||
| max. cycle | 32 ms | ||
| communication functions / header | |||
| PG/OP communication | Yes | ||
| ● Number of connectable OPs with message processing | 63; When using Alarm_S/SQ and Alarm_D/DQ | 95; When using Alarm_S/SQ and Alarm_D/DQ | |
| ● Number of connectable OPs without message processing | 63 | 95 | |
| Data record routing | Yes | ||
| Global data communication | |||
| ● supported | Yes | ||
| ● Number of GD loops, max. | 16 | ||
| ● Number of GD packets, transmitter, max. | 16 | ||
| ● Number of GD packets, receiver, max. | 32 | ||
| ● Size of GD packets, max. | 54 byte | ||
| ● Size of GD packet (of which consistent), max. | 1 variable | ||
| S7 basic communication | |||
| ● supported | Yes | ||
| ● User data per job, max. | 76 byte | ||
| ● User data per job (of which consistent), max. | 1 variable | ||
| S7 communication | |||
| ● supported | Yes | ||
| ● as server | Yes | ||
| ● as client | Yes | ||
| ● User data per job, max. | 64 kbyte | ||
| ● User data per job (of which consistent), max. | 462 byte; 1 variable | ||
| S5 compatible communication | |||
| ● supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | ||
| ● User data per job, max. | 8 kbyte | ||
| ● User data per job (of which consistent), max. | 240 byte | ||
| ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 64/64 | ||
| Standard communication (FMS) | |||
| ● supported | Yes; Via CP and loadable FB | ||
| Number of connections | |||
| ● overall | 64 | 96 | |
| ● usable for PG communication | 63 | 95 | |
| — reserved for PG communication | 1 | ||
| — adjustable for PG communication, max. | 0 | ||
| ● usable for OP communication | 63 | 95 | |
| — reserved for OP communication | 1 | ||
| — adjustable for OP communication, max. | 0 | ||
| ● usable for S7 basic communication | 62 | 94 | |
| — reserved for S7 basic communication | 0 | ||
| — adjustable for S7 basic communication, max. | 0 | ||
| ● usable for S7 communication | 62 | 94 | |
| — reserved for S7 communication | 0 | ||
| — adjustable for S7 communication, max. | 0 | ||
| ● usable for routing | 31 | 47 | |
| — reserved for routing | 0 | ||
| — adjustable for routing, max. | 0 | ||
| S7 message functions | |||
| Number of login stations for message functions, max. | 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) | 95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) | |
| Symbol-related messages | Yes | ||
| SCAN procedure | Yes | ||
| Program alarms | Yes | ||
| Process diagnostic messages | Yes | ||
| simultaneously active Alarm_S blocks, max. | 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks | ||
| Alarm 8-blocks | Yes | ||
| ● Number of instances for alarm 8 and S7 communication blocks, max. | 4 000 | ||
| ● preset, max. | 600 | ||
| Process control messages | Yes | ||
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 32 | ||
| Number of messages | |||
| ● overall, max. | 1 024 | ||
| ● in 100 ms grid, max. | 128 | ||
| ● in 500 ms grid, max. | 512 | ||
| ● in 1000 ms grid, max. | 1 024 | ||
| Number of additional values | |||
| ● with 100 ms grid, max. | 1 | ||
| ● with 500, 1000 ms grid, max. | 10 | ||
| Test commissioning functions | |||
| Status block | Yes; Up to 2 simultaneously | Yes; Up to 16 simultaneously | |
| Single step | Yes | ||
| Number of breakpoints | 4 | 16 | |
| Status/control | |||
| ● Status/control variable | Yes; Up to 16 variable tables | ||
| ● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | ||
| ● Number of variables, max. | 70; Status/control | ||
| Forcing | |||
| ● Forcing | Yes | ||
| ● Forcing, variables | Inputs, outputs, bit memories, peripheral inputs, peripheral outputs | ||
| ● Number of variables, max. | 512 | ||
| Diagnostic buffer | |||
| ● present | Yes | ||
| ● Number of entries, max. | 3 200 | ||
| — adjustable | Yes | ||
| — preset | 120 | ||
| Service data | |||
| ● can be read out | Yes | ||
| Standards, approvals, certificates | |||
| CE mark | Yes | ||
| CSA approval | Yes | ||
| UL approval | Yes | ||
| cULus | Yes | ||
| FM approval | Yes | ||
| RCM (formerly C-TICK) | Yes | ||
| KC approval | Yes | ||
| EAC (formerly Gost-R) | Yes | ||
| Use in hazardous areas | |||
| ● ATEX | ATEX II 3G Ex nA IIC T4 Gc | ||
| Ambient conditions | |||
| Ambient temperature during operation | |||
| ● min. | 0 °C | ||
| ● max. | 60 °C | ||
| configuration / header | |||
| Configuration software | |||
| ● STEP 7 | Yes | ||
| configuration / programming / header | |||
| ● Command set | see instruction list | ||
| ● Nesting levels | 7 | ||
| ● Access to consistent data in process image | Yes | ||
| ● System functions (SFC) | see instruction list | ||
| ● System function blocks (SFB) | see instruction list | ||
| Programming language | |||
| — LAD | Yes | ||
| — FBD | Yes | ||
| — STL | Yes | ||
| — SCL | Yes | ||
| — CFC | Yes | ||
| — GRAPH | Yes | ||
| — HiGraph® | Yes | ||
| configuration / programming / number of simultaneously active SFC / header | |||
| — DPSYC_FR | 2; SFC 11; per interface | ||
| — D_ACT_DP | 8; SFC 12; per interface | ||
| — RD_REC | 8; SFC 59; per interface | ||
| — WR_REC | 8; SFC 58; per interface | ||
| — WR_PARM | 8; SFC 55; per interface | ||
| — PARM_MOD | 1; SFC 57; per interface | ||
| — WR_DPARM | 2; SFC 56; per interface | ||
| — DPNRM_DG | 8; SFC 13; per interface | ||
| — RDSYSST | 8 | 8; SFC 51 | |
| — DP_TOPOL | 1; SFC 103; per interface | ||
| configuration / programming / number of simultaneously active SFB / header | |||
| — RDREC | 8; SFB 52; per interface, but not more than 32 across all external interfaces | ||
| — WRREC | 8; SFB 53; per interface, but not more than 32 across all external interfaces | ||
| Know-how protection | |||
| ● User program protection/password protection | Yes | ||
| ● Block encryption | Yes; With S7 block Privacy | ||
| Dimensions | |||
| Width | 25 mm | ||
| Height | 290 mm | ||
| Depth | 219 mm | ||
| Weights | |||
| Weight, approx. | 720 g | ||