General technical data
product brand name   SIRIUS
product designation   Soft starter
product feature    
● integrated bypass contact system   Yes
● thyristors   Yes
product function    
● intrinsic device protection   Yes
● motor overload protection   Yes
● evaluation of thermistor motor protection   No
● external reset   Yes
● adjustable current limitation   Yes
● inside-delta circuit   No
product component motor brake output   No
insulation voltage rated value V 600
degree of pollution   3, acc. to IEC 60947-4-2
blocking voltage of the thyristor maximum V 1 600
reference code according to EN 61346-2   Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750   G
Power Electronics
operational current    
● at 40 °C rated value A 32
● at 50 °C rated value A 29
● at 60 °C rated value A 26
yielded mechanical performance for 3-phase motors    
● at 230 V    
— at standard circuit at 40 °C rated value kW 7.5
● at 400 V    
— at standard circuit at 40 °C rated value kW 15
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value hp 7.5
operating frequency rated value Hz 50 ... 60
relative negative tolerance of the operating frequency % -10
relative positive tolerance of the operating frequency % 10
operating voltage at standard circuit rated value V 200 ... 480
relative negative tolerance of the operating voltage at standard circuit % -15
relative positive tolerance of the operating voltage at standard circuit % 10
minimum load [%] % 20
adjustable motor current for motor overload protection minimum rated value A 17
continuous operating current [% of Ie] at 40 °C % 115
power loss [W] at operational current at 40 °C during operation typical W 13
Control circuit/ Control
type of voltage of the control supply voltage   AC/DC
control supply voltage frequency 1 rated value Hz 50
control supply voltage frequency 2 rated value Hz 60
relative negative tolerance of the control supply voltage frequency % -10
relative positive tolerance of the control supply voltage frequency % 10
control supply voltage 1 at AC at 50 Hz V 110 ... 230
control supply voltage 1 at AC at 60 Hz V 110 ... 230
relative negative tolerance of the control supply voltage at AC at 50 Hz % -15
relative positive tolerance of the control supply voltage at AC at 50 Hz % 10
relative negative tolerance of the control supply voltage at AC at 60 Hz % -15
relative positive tolerance of the control supply voltage at AC at 60 Hz % 10
control supply voltage 1 at DC V 110 ... 230
relative negative tolerance of the control supply voltage at DC % -15
relative positive tolerance of the control supply voltage at DC % 10
display version for fault signal   red
Mechanical data
size of engine control device   S0
width mm 45
height mm 125
depth mm 155
fastening method   screw and snap-on mounting
mounting position   With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t
required spacing with side-by-side mounting    
● upwards mm 60
● at the side mm 15
● downwards mm 40
wire length maximum m 300
number of poles for main current circuit   3
Connections/ Terminals
type of electrical connection    
● for main current circuit   screw-type terminals
● for auxiliary and control circuit   screw-type terminals
number of NC contacts for auxiliary contacts   0
number of NO contacts for auxiliary contacts   2
number of CO contacts for auxiliary contacts   1
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point    
● solid   2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm²
● finely stranded with core end processing   2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
type of connectable conductor cross-sections for AWG cables for main contacts for box terminal    
● using the front clamping point   1x 8, 2x (16 ... 10)
type of connectable conductor cross-sections for auxiliary contacts    
● solid   2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing   2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections for AWG cables    
● for auxiliary contacts   2x (20 ... 14)
● for auxiliary contacts finely stranded with core end processing   2x (20 ... 16)
Ambient conditions
installation altitude at height above sea level m 5 000
environmental category    
● during transport according to IEC 60721   2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 60721   1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 60721   3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature    
● during operation °C -25 ... +60
● during storage °C -40 ... +80
derating temperature °C 40
protection class IP on the front according to IEC 60529   IP20
touch protection on the front according to IEC 60529   finger-safe, for vertical contact from the front
Environmental footprint
Environmental Product Declaration(EPD)   Yes
global warming potential [CO2 eq] total kg 121
global warming potential [CO2 eq] during manufacturing kg 4.24
global warming potential [CO2 eq] during sales kg 0.207
global warming potential [CO2 eq] during operation kg 117
global warming potential [CO2 eq] after end of life kg -0.229
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor    
● at 220/230 V    
— at standard circuit at 50 °C rated value hp 7.5
● at 460/480 V    
— at standard circuit at 50 °C rated value hp 20
contact rating of auxiliary contacts according to UL   B300 / R300