Single Phase Double Conversion High Performance
The HT11 Series Tower Online UPS offers reliable, uninterrupted power for critical applications. Available in both standard models with built-in batteries and long backup models, this single-phase UPS combines compact design with high power density. Featuring advanced DSP-controlled double conversion technology, it is an ideal solution for computers, telecom systems, and other sensitive electronics. Available capacities include 6kVA, 10kVA, 15kVA, and 20kVA.
High Efficiency – Up to 95%
True Power Output – kVA = kW, Output Power Factor = 1
Advanced 3-Level Technology – Optimized for complex loads
Customizable Battery Configuration – Battery quantity adjustable via LCD panel
Smart Charging Management – Prolongs battery lifespan effectively
Compact & Powerful – Smaller footprint with higher power density
Parallel Capability – Supports up to 4 units in parallel
Optional 12A Charger – Suitable for charging high-capacity battery banks
Perfect for mission-critical environments that demand clean and continuous power, the HT11 Series delivers performance, reliability, and flexibility—all in a compact tower form.
Specifications
| HT1106XS | HT1106XL | HT1110XS | HT1110XL | |
| INPUT | ||||
| Cold Start | YES Default output frequency will be 50Hz or settable |
|||
| Acceptable Input Voltage | 110VAC~288VAC | |||
| 100% load@>176VAC | ||||
| 90% load@>154VAC | ||||
| 75% load@>132VAC | ||||
| 50% load@>110VAC | ||||
| Phase | Single phase in,single phase out | |||
| Transfer Voltage Range | 220VAC/230VAC/240VAC(PF=1) | |||
| -Line low transfer | 110VAC | |||
| -Line low recovery | 121VAC | |||
| -Line high transfer | 288VAC | |||
| -Line high recovery | 281VAC | |||
| Input Current | ||||
| -Rating(nominal input voltage) | 30A/220V | 34A/220V | 49A/220V | 53A/220V |
| Input Power Factor | ≥0.99 | |||
| Input current distortion | <4% | |||
| Input Frequency Range | 40~70Hz | |||
| OUTPUT | ||||
| Frequency adaptable | Settable | |||
| Power | ||||
| -Power | 6KVA | 10KVA | ||
| -Power(kW) | 6KW | 10KW | ||
| Output Voltage | ||||
| -Waveform(Bat. Mode) | Pure Sine Wave | |||
| -Nominal voltage | 220VAC/230VAC/240VAC | |||
| -Voltage regulation | ± 1 % | |||
| -Voltage distortion | ≤1% THD, linear load | |||
| ≤ 5% THD, non linear load | ||||
| Output Frequency | ||||
| -Synchronization range | 50/60 HZ±5Hz default, settable | |||
| -Battery mode | (50±0.1) Hz default | |||
| Transfer Time | ||||
| -Line mode to battery mode | 0ms | |||
| -Inverter to bypass | 0ms | |||
| Efficiency | ||||
| -Line mode with battery full charged | 95%MAX | |||
| -ECO mode | 98.0% | |||
| Noise(1m away) | <58dB | |||
| Overload Capability(Inverter) | 105% to 110% : Transfer to bypass after 10 mins. | |||
| 111% to 125% : Transfer to bypass after 1 mins. | ||||
| 126% to 150%: Transfer to bypass after 30s | ||||
| Overload Capability (Bypass Mode) | less than 125%: long time running | |||
| 126% to 130% :Shutdown in 5 mins | ||||
| 131% to 150% :Shutdown in 1 mins | ||||
| > 150% :Shutdown in 200 ms | ||||
| Crest Ratio | 3:1 | |||
| BATTERY | ||||
| Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries |
| Quantity | 16PCS default, 20PCS settable | 16-20PCS settable | 16PCS default, 20PCS settable | 16-20PCS settable |
| DC Voltage | 192VDC default, settable | |||
| Back-up Time | 4.5mins @80%load | Depend on the capacity of external batteries | 2.5mins @80%load | Depend on the capacity of external batteries |
| Charger | ||||
| -Charging current (max) | 1A, settable | 5A max,settable | 1A,settable | 5A max,settable |
| -Float Charging Voltage | 2.25V/cell default, setttable via software | |||
| -Boost Charging Voltage | 2.25V/cell default, setttable via software | |||
| -Charging time | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
| Leakage current | <3mA | |||
| Indicator & Alarm | ||||
| -Display | LED+LCD | |||
| Inteface | ||||
| -Smart RS232 | Standard Cable support INVT Power Monitor Software | |||
| -EPO | NC | |||
| -RS485(option) | Installed in the intelligent slot | |||
| -SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||
| Option | ||||
| -Intelligent Kits | DB9 port, dry contact | |||
| -parallel | 4 units paralleled | |||
| -Super charger (12A) | digitally controlled, 4-steps charge, settable,@PF0.9 | |||
| -USB | B-type USB port | |||
| -SNMP Kits | Pluggable type | |||
| Working Enviroment | ||||
| Mechanical | ||||
| -W%sD%sH (mm) | 190*426*705 | 190*426*336 | 190*485*705 | 190*485*336 |
| -Net Weight (KG) | 56 | 14 | 60 | 16 |
| -Package Weight (KG) | 61 | 15 | 70 | 17 |
| -Rack / Tower | Tower | |||
| Color | Black default | |||
| HT1115XL | HT1120XL | |
| INPUT | ||
| Cold Start | YES Default output frequency will be 50Hz or settable |
|
| Acceptable Input Voltage | 110VAC~288VAC | |
| 100% load@>176VAC | ||
| 90% load@>154VAC | ||
| 75% load@>132VAC | ||
| 50% load@>110VAC | ||
| Phase | Single phase in,single phase out | |
| Transfer Voltage Range | 220/230/240VAC | |
| -Line low transfer | 110VAC | |
| -Line low recovery | 121VAC | |
| -Line high transfer | 288VAC | |
| -Line high recovery | 281VAC | |
| Input Current | ||
| -Rating(nominal input voltage) | 25A/380V | 33A/380V |
| -Input Power Factor | ≥0.99 | |
| -Input current distortion | ≤4% | |
| -Input Frequency Range | 40~70Hz | |
| OUTPUT | ||
| Frequency adaptable | Settable | |
| Power | ||
| -Power | 15KVA | 20KVA |
| -Power(kW) | 15KW | 20KW |
| Output Voltage | ||
| -Waveform(Bat. Mode) | Pure Sine Wave | |
| -Nominal voltage | L-N 220VAC/230VAC/240VAC, 200VAC/208VAC(PF=0.9) | |
| -Voltage regulation | ± 1 % | |
| -Voltage distortion | ≤1% THD, linear load | |
| ≤5% THD, non linear load | ||
| Output Frequency | ||
| -Synchronization range | ±5Hz default, settable | |
| -Battery mode | (50±0.1) Hz default | |
| Transfer Time | ||
| -Line mode to battery mode | 0ms | |
| -Inverter to bypass | 0ms | |
| Efficiency | ||
| -Line mode with battery full charged | 94%@100% load, 94.5%@70% load | |
| -ECO mode | 98.0% | |
| Noise(1m away) | <62dB | |
| Overload Capability(Inverter) | 105% to 110% : Transfer to bypass after 10 mins. | |
| 111% to 125% : Transfer to bypass after 1 mins. | ||
| 126% to 150%: Transfer to bypass after 30s | ||
| Overload Capability (Bypass Mode) | less than 125%: long time running | |
| 126% to 130% :Shutdown in 5 mins | ||
| 131% to 150% :Shutdown in 1 mins | ||
| > 150% :Shutdown in 200 ms | ||
| BATTERY | ||
| Quantity | 16-20PCS settable | |
| DC Voltage | 192VDC default, settable | |
| Charger | ||
| -Charging current (max) | 5A max,settable | |
| -Float Charging Voltage | 2.25V/cell default, setttable via software | |
| -Boost Charging Voltage | 2.25V/cell default, setttable via software | |
| Indicator & Alarm | ||
| -Display | LED+LCD | |
| Inteface | ||
| -Smart RS232 | Standard Cable support INVT Power Monitor Software | |
| -EPO | NC, NO settable, forbidden default | |
| -RS485(option) | Installed in the intelligent slot | |
| -SNMP(option) | Power Managment from SNMP Manager and Web Browser | |
| Option | ||
| -Intelligent dry contact | DB9 port or terminal | |
| -parallel | 4 units paralleled | |
| -Super charger (12A) | digitally controlled, 4-steps charge, settable | |
| -USB | B-type USB port | |
| -SNMP Kits | Pluggable type | |
| Working Enviroment | ||
| -storage | -40~70℃ | |
| -working | 0~40℃, huminity 95% non condesation, attitude<1500m (@full load) | |
| Mechanical | ||
| -W%sD%sH (mm) | 190*485*480 | |
| -Net Weight (KG) | 30 | |
| -Package Weight (KG) | 33 | |
| -Rack / Tower | Tower | |
| Color | Black default | |