96% efficiency with ECO-mode optimization.
PF >0.99 and THDi <3% with full-load capacity.
50%+ longer battery life vs. traditional solutions.
30% smaller footprint than competitors, with modular subsystems for <15-minute component swaps.
High power density design with full front maintenance and support for top and bottom cable entry methods, saving installation space.
MODEL | HTD33120 | HTD33160 | HTD33200 |
System Capacity | 120kVA | 160kVA | 200kVA |
Power Module Capacity | 60kVA/60kW | 80kVA/80kW | 100kVA/100kW |
Main Input | |||
Grid System | 3P+N+PE | ||
Rated Input Voltage | 380/400/415VAC (line-line) | ||
Rated Frequency | 50/60Hz | ||
Input Voltage Range | 323~478Vac (line-line), full load @ 30~40℃ 323~138Vac (line-line), load decrease linearly from 100% load to 30% load @ 30~40℃ |
||
Input Frequency Range | 40Hz~70Hz | ||
Input Power Factor | >0.99 | ||
Input Current THDi | <3% (full Linear load) | ||
Bypass | |||
Rated Bypass Voltage | 380/400/415VAC (line-line) | ||
Rated Bypass Frequency | 50/60Hz | ||
Bypass Voltage Range | Settable, default -20%~+15% Upper limited: +10%, +15%, +20%, +25% Lower limited: -10%, -15%, -20%, -30%, -40% |
||
Bypass Frequency Range | Settable, ±1Hz, ±3Hz, ±5Hz | ||
Bypass Overload | 125%, long term operation 125%~130%, 10 minutes 130%~150%, 1 minute >150%, 300ms |
||
Output | |||
Rated Voltage | 380/400/415VAC (line-line) | ||
Rated Frequency | 50/60Hz | ||
Output Power Factor | 1 | ||
Voltage Precision | ±1% | ||
Transient Response | <5% (0% - 100% -0% step load) | ||
Transient Recovery | < 40ms (0% - 100% -0% step load) | ||
Output Voltage THDu | <1%, linear load <5%, non-linear load (IEC/EN62040-3) |
||
Inverter Overload | <110%, 60 mins 110%~125%, 10mins 125%~150%, 1min >150%, 200ms |
||
Frequency Regulation | 50/60Hz±0.1% | ||
Synchronized Range | Settable, ±0.5Hz~±5Hz, default ±3Hz | ||
Synchronized Slew Rate | Settable, 0.5Hz/S~3Hz/S, default 0.5Hz/S | ||
Battery and Charger | |||
Battery Rated Voltage | ±240VDC 30pcs derated 0.7 32~34pcs derated 0.8 36~38pcs derated 0.9 40~48pcs non-derating |
||
Charger Voltage Precision | 1% | ||
Charger Power | max=15% * Output active power | ||
Effiency | |||
Normal Operation | >96% | ||
Battery Operation | >95% | ||
Power Module Weight (kg) | 44.8 | 51.2 | 53.5 |
System | |||
Display | LCD + LED + Color touch screen | ||
Interface | RS485, USB, CAN, Programmable dry contact, 2 intelligent card slots, 1 expandable dry contact slot | ||
Option | SNMP card, AS400, Parallel kit, Lightning protection components, Copper bar, LBS, SMS alarm, RS485 expansion card |
||
Environment | |||
Operation Temperature | 0~40 ℃ | ||
Storage Temperature | -40~70 ℃ | ||
Relative Humidity | 0 ~ 95% Non condensing | ||
Noise (1 meter) | 75dB @ 100% load, 70dB @ 45% load | ||
Altitude | <1000m, Load derated 1% per 100m From 1000~2000m | ||
Physical | |||
Cabinet Dimension (W*D*H, mm) |
480*1100*1200 | ||
Cabinet Weight (kg) | 78.8 | ||
Power Module Dimension (W*D*H, mm) |
440*795*174 | ||
Power Module Weight (kg) | 44.8 | 51.2 | 53.5 |