| Model | KV-7300 | |||
| Type | CPU unit | |||
| General specifications | Power voltage | KV-5000/3000 Series System configuration using an expansion unit: 24 VDC (±10 %) | ||
| Operating ambient temperature | KV-5000/3000 Series System configuration using an expansion unit: 0 to +50 °C (No freezing) | |||
| Operating ambient humidity | KV-5000/3000 Series System configuration using an expansion unit: 10 to 95 % RH (No condensation) | |||
| Ambient temperature for storage | KV-5000/3000 Series System configuration using an expansion unit: -20 to +70 °C | |||
| Storage relative humidity | KV-5000/3000 Series System configuration using an expansion unit: 10 to 95 % RH (No condensation) | |||
| Operating environment | No dust or corrosive gas | |||
| Altitude | 2,000 m or less | |||
| Noise immunity | 1,500 Vp-p or more, Pulse width: 1 µs, 50 ns (based on noise simulator), IEC standard-compliant (IEC 61000-4-2/3/4/6) | |||
| Withstand voltage | 1,500 VAC for 1 minute (between the power terminals and the I/O terminals, and between the external terminals and the housing) | |||
| Insulation resistance | 50 M!& or more (between the power terminals and the I/O terminals, and between the external terminals and the housing, with 500 VDC megohmmeter) | |||
| Shock resistance | Acceleration: 150 m/s2, Operation time: 11 ms, 2 times in each of the X, Y, and Z directions | |||
| Pollution degree | 2 | |||
| Vibration resistance | Intermittent vibration | Frequency 5 to 9 Hz | Half amplitude: 3.5 mm*1 | |
| Frequency 9 to 150 Hz | Acceleration: 9.8 m/s2*1 | |||
| Continuous vibration | Frequency 5 to 11 Hz | Half amplitude: 1.75 mm*1 | ||
| Frequency 9 to 150 Hz | Acceleration: 4.9 m/s2*1 | |||
| Performance specifications | Arithmetic control mode | Stored program mode | ||
| I/O control mode | Refresh mode | |||
| Program language | Expanded ladder, KV Script, mnemonic | |||
| Number of commands | Basic instruction: 80 classes, 181 instructions | |||
| Instruction execution speed | Basic instruction: Min. 0.96 ns | |||
| CPU memory capacity | 21 MB | |||
| Program capacity | Approx. 160k steps | |||
| Maximum number of units to be installed | 16 units (only with KV-7000 Series expansion unit) | |||
| Maximum number of I/O points | Maximum 3,072 points for expansion (KV-EB1S/KV-EB1R: 2 units used, 64-point unit used) | |||
| Bit device | Input relay R | Total 16,000 points 1 bit | ||
| Output relay R | ||||
| Internal auxiliary relay R | ||||
| Link relay B | 32,768 points 1 bit | |||
| Internal auxiliary relay MR | 64,000 points 1 bit | |||
| Latch relay LR | 16,000 points 1 bit | |||
| Control relay CR | 1,280 points 1 bit | |||
| Word device | Timer T | 4,000 points 32 bits | ||
| Counter C | ||||
| Data memory DM | 65,535 points 16 bits | |||
| Expansion data memory EM | ||||
| File register | Current bank FM | 524,288 points 16 bits | ||
| Dial mode ZF | ||||
| Link register W | 32,768 points 16 bits | |||
| Temporary data memory TM | 512 points 16 bits | |||
| Index register Z | 12 points 32 bits | |||
| Control memory CM | 6,000 points 16 bits | |||
| Device comment | Approx. 102,000 | |||
| Label | Approx. 131,000 | |||
| Power failure hold function | Program memory | Flash ROM can be written 10,000 times | ||
| Device | Nonvolatile RAM | |||
| Calendar timer | Backup condenser lasts approx. 15 days (25 °C) | |||
| Self-diagnosis function | CPU error, RAM error, other | |||
| Internal current consumption | 200 mA or less | |||
| Weight | CPU unit: Approx. 270 g | |||