Large Display Meter (BCD Input)
| 4013 | - | □ | - | □ | - | □ | - | □ | - | □ |
| ① | ② | ③ | ④ | ⑤ |
| Protection Degree |
IP44 (Wall-mount and Hanging-mount) IP65 (Sticking-mount with water-proof works) |
|---|---|
| Display | 5 digit red or green LED (character height 56mm) with zero-suppress function. |
| Unit display | Optional unit display is possible. |
| Numbers | BCD code parallel input (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, b, C, d, E, F) |
| Polarity(POL) | (-) sign (5×9 mm), L at positive logic, H at negative logic |
| Decimal Point(DP) | Light on L level |
| P/N logic switching | Logic switching for polarity and numbers. H at positive logic, L at negative logic. |
| Latch (LATCH) | Hold read out (numbers, polarity and decimal point) at L level |
| Synchronization(SYNC) | Display is updated at the rising point of the external synchronization signal. |
| Lamp test (LT) | Flash all segments from 100 to 104 digit, polarity and decimal point by short-circuiting DATA and COM with a non-voltage contact. |
| Insulation Resistance | DC 500 V More than 50 MΩ |
| Withstand Voltage | |
| Power Supply | AC 100 to 120 V, AC 200 to 240 V (50/60 Hz), DC 24 V |
| Tolerance of source voltage | AC 85 to 132V, AC 170 to 250 V, DC 20 to 30 V |
| Power Consumption | Approx. 10 VA at AC 100 V, Approx. 200 mA at DC 24 V |
| Operating Temperature | 0 to 50°C |
| Storage Temperature | -20 to 70°C |
| Weight | Approx. 2.5 kg |
| Accessory | Amphenol connector (57-30360, by DDK) |