Digital Panel Meter
| 451F | - | □ | - | □ | - | □ |
| ① | ② | ③ |
| Code | Measuring range | Input impedance | Accuracy | Over load |
|---|---|---|---|---|
| 22A | 99.99 mVrms | 100 kΩ | ±(0.2% of rdg + 10digits) | AC 10 V |
| 23A | 999.9 mVrms | 100 kΩ | AC 100 V | |
| 24A | 9.999 Vrms | 1 MΩ | AC 400 V | |
| 25A | 99.99 Vrms | 1.9 MΩ | ||
| 26A | 699.9 Vrms | 1.9 MΩ | ±(0.3% of rdg + 10digits) | AC 700 V |
| 32 | 99.99 μArms | 1 kΩ | AC 20 mA | |
| 33 | 999.9 μArms | 100 Ω | AC 50 mA | |
| 34 | 9.999 mArms | 10 Ω | AC 150 mA | |
| 35 | 99.99 mArms | 1 Ω | AC 500 mA | |
| 36 | 999.9 mArms | 0.1 Ω | ±(0.5% of rdg + 10digits) | AC 2 A |
| 5.000 Arms | 0.01 Ω | AC 10 A |
| Code | Power source voltage |
|---|---|
| A | AC 100 to 240 V |
| B | DC 12 to 24 V |
| C | DC 110 V |
| Code | Data Output | Output impedance | Tolerable Load resistor |
|---|---|---|---|
| Blank | - | ||
| 09 |
Analog output DC 0 to 10 V (Available scaling, Default: 1 to 5 V) |
Less than 0.1 Ω |
More than 500 Ω (DC 1 to 5 V) More than 1 kΩ (DC 0 to 10 V) |
| 29 |
Analog output DC 0 to 20 mA (Available scaling, Default: 4 to 20 mA) |
More than 5 MΩ | 0 to 600 Ω (DC 4 to 20 mA) |
| BP | BCD output (TTL level positive logic) | - | |
| BN | BCD output (TTL level negative logic) | - | |
| DP | BCD output (transistor output, source type) | - | |
| DN | BCD output (transistor output, sink type) | - | |
| E0 | RS-232C | - | |
| E1 | RS-485 | - | |
| EC | Decimal point external control | - | |
| Code | Data output |
|---|---|
| Blank | No output |
| E0 | RS-232C |
| E1 | RS-485 |
| EC | Decimal point external control |
| Display | 0 to 99999, red or green LED (character height 15.2 mm), with zero-suppress function. |
|---|---|
| Scaling offset | 0 to +9999 |
| Scaling full scale | 0 to +9999 |
| Display cycle | Selectable from 500ms, 1s, 2s, 4s, 5s |
| Resolution | 1/10000 |
| Sampling rate | Approx. 2 times / s. |
| Response | within 2 samplings or 1 display cycle, whichever longer |
| Input method | Single ended, floating input |
| A/D conversion | ⊿-∑conversion method |
| Noise Rejection | Noise through power supply line - 1000 V (at AC voltage power supply) |
| Insulation Resistance | DC 500 V, More than 100 MΩ |
| Withstand Voltage |
Input terminals - External case: AC 1500 V each for 1min. Power supply terminals - External case: AC 1500 V each for 1min. Power supply terminals - Input and output terminals: AC 500 V each for 1min. Input terminals - Output terminals: AC 500 V each for 1min. |
| Power Supply | AC 100 to 240V (90 to 250 V) 50/60 Hz, DC 12 to 24 V (9 to 32 V) |
| Power Consumption | Approx. 9 VA at 100 V AC, 11.5 VA at 200 V AC, 400 mA at 12 V. 200 mA at 24 V DC. |
| Operating Temperature | 0 to 50°C |
| Storage Temperature | -20 to 70°C |
| Weight | Approx. 300 g (60 g of the power supply unit) |
| Housing protection | IP65 for the front panel, IP20 for the rear case, IP00 for terminals |