| Specification / Model |
NRW-80H NRW-80HL |
NRW-110H NRW-110HL |
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
![]() |
![]() |
||||||||||||||
| H : High value setting, relay contact output HL : High and Low value setting, relay contact output | ||||||||||||||||
|
Dimension (mm) |
80(W)×80(H) | ● | - | |||||||||||||
| 110(W)×110(H) | - | ● | ||||||||||||||
| Weight (1 mA d.c. rated) | approx. 550 g | approx. 1,400 g | ||||||||||||||
| Type | Wide angle | |||||||||||||||
| Input (*) | DC Current | (Moving coil) | 10 μA to 5 A | 1 mA, 10 mA to 5 A | ||||||||||||
| DC Voltage | (Moving coil) | 10 mV to 300 V | 1 V to 300 V | |||||||||||||
| Receiver | (Moving coil) |
4 to 20 mA, 1 to 5 V(500 kΩ) |
4 to 20 mA, 1 to 5 V(4 kΩ), 1 to 5 V(1 MΩ) |
|||||||||||||
| AC Current | (average) | 1 to 300 mA (with 7311) | 1 to 300 mA | |||||||||||||
| (r.m.s., 1 A or more) | 1 to 5 A (CT incorporated), 10 to 30 A (with 7311) | |||||||||||||||
| AC Voltage | (average) | 10 to 300 V | ||||||||||||||
| Display | Accuracy | Class 1.5 | - | ● | ||||||||||||
| Class 2.5 | ● | - | ||||||||||||||
| Scale length | 121 mm | 170 mm | ||||||||||||||
| Scale divisions | 30 to 50 | |||||||||||||||
| Scale Pointer | Wide angle, black | |||||||||||||||
| Scale plate color | White | |||||||||||||||
| Cover color | Black | |||||||||||||||
| Output | Operation type | Optical | - | ● | ||||||||||||
| Electrical | ● | - | ||||||||||||||
| Output | Hold (latching relay for NRW-110) | |||||||||||||||
| Pointer | Knife shape H(High) : Red, L(Low): Green | |||||||||||||||
| Setting range | 0 to 100 % of scale for H and L | |||||||||||||||
| Setting | HL (High / Low) or H (High) | |||||||||||||||
| Minimum setting range (*2) | Less than 3 % | |||||||||||||||
| Pick up accuracy (*2) | Less than 1.5 % | |||||||||||||||
| Deadband (*2) | Less than 0.5 % | |||||||||||||||
|
Temp. coefficient (*2) (pick up value change at 23°C ± 10°C) |
Less than 0.3 % | |||||||||||||||
|
Power regulation (*2) (pick up value change at rated voltage ± 10%) |
Less than 0.3 % | |||||||||||||||
| Output contact | 1 transfer for H and L (NRW-110: Latching relay) | |||||||||||||||
| Contact rate (load resistance) |
250 V, 3 A a.c. 30 V, 2 A d.c. |
|||||||||||||||
| Power on delay | ○ | ○ | ||||||||||||||
| Operation delay | ○ | - | ||||||||||||||
| 100/110,200/220 V AC | ● | ● | ||||||||||||||
| 24 V DC | ○ | ○ | ||||||||||||||
| Power consumption | 2 VA or less | |||||||||||||||
| Operating temperature | 0 – 50°C | |||||||||||||||
| Operating humidity | 30 to 90% RH (no condensation) | |||||||||||||||
| Weight (1 mA d.c. rated) | approx. 550 g | approx. 1,400 g | ||||||||||||||
●:Standard, ○:Option