FLUKE - Digital Multimeter
Brand: Fluke
Model: Fluke 115
| Specifications | ||
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution |
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts1 True RMS | Range/resolution |
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution |
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution |
1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
|
AC amps True RMS (45 Hz to 500Hz) |
Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy |
1.5% + 3 20 A overload for 30-seconds max |
|
| DC amps | Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy |
1.0% + 3 20 A overload for 30-seconds max |
|
| Hz (V or A input)2 | Range/resolution |
99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz |
| Accuracy | 0.1% + 2 | |