| Wind Speed | |
|---|---|
| Range | : 0÷60 m/s |
| Uncertainty | : ±0.5 m/s or 5% reading |
| Resolution | : 0,1 m/s |
| Wind Direction | |
| Range | : 0÷360° |
| Uncertainty | : ± 5° @ wind speed > 2.2 m/s |
| Kompass | : ±2° uncertanty |
| Resolution | : 1° |
| Temperature | |
| Range | : -40÷+50 °C |
| Uncertainty | : ±0.2°C |
| Resolution | : 0,1°C |
| RH% | |
| Range | : 0÷100% |
| Uncertainty | : ±3% |
| Resolution | : 1% |
| Pressure | |
| Range | : 600÷1100 hPa |
| Uncertainty | : ±0.35 hPa |
| Resolution | : 0,1 hPa |
| General | |
| Power supply | : 8÷36 VDC |
| Output | : RS-232, RS-485, SDI-12 |
| Power consumption | : 25 mA |
| Cable | : L = 10 m |
| Operative limits | : -50÷+70 °C |
| Data logger compatibility | : On RS232 port: M-Log (all modelsi), E-Log (all models) |