With its nano-order speed basic command processes, the next generation MELSEC-Q Series dramatically improves system and machine performance.
| CPU - Q MODE | |
| Q00JCPU | CPU, PROGRAM: 8K STEPS |
| Q00CPU | CPU, PROGRAM: 8K STEPS |
| Q01CPU | CPU, PROGRAM: 14K STEPS |
| Q02CPU | CPU, PROGRAM: 28K STEPS |
| Q02HCPU | CPU, PROGRAM: 28K STEPS, HIGH SPEED |
| Q06HCPU | CPU, PROGRAM: 60K STEPS, HIGH SPEED |
| Q12HCPU | CPU, PROGRAM: 124K STEPS, HIGH SPEED |
| Q25HCPU | CPU, PROGRAM: 252K STEPS, HIGH SPEED |
| CPU - PROCESS CPU MODULE | |
| Q12PHCPU | CPU, PROGRAM: 124K STEPS, PROCESS CPU |
| Q25PHCPU | CPU, PROGRAM: 252K STEPS, PROCESS CPU |
| BASE UNIT, EXTENSION UNITS | |
| Q33B | POWER SUPPLY + CPU + 3 SLOTS FOR Q SERIES I/O, CE/UL/cUL |
| Q35B | POWER SUPPLY + CPU + 5 SLOTS FOR Q SERIES I/O, CE/UL/Cul |
| Q38B | POWER SUPPLY + CPU + 8 SLOTS FOR Q SERIES I/O, CE/UL/cUL |
| Q312B | POWER SUPPLY + CPU + 12 SLOTS FOR Q SERIES I/O, CE/UL/cUL |
| Q63B | POWER SUPPLY + 3 I/O SLOTS, FOR Q SERIES MODULE, CE/UL/cUL |
| Q65B | POWER SUPPLY + 5 I/O SLOTS, FOR Q SERIES MODULE, CE/UL/cUL |
| Q68B | POWER SUPPLY + 8 I/O SLOTS, FOR Q SERIES MODULE, CE/UL/cUL |
| Q612B | POWER SUPPLY + 12 I/O SLOTS, FOR Q SERIES MODULE, CE/UL/cUL |
| Q52B | 2 I/O SLOTS, FOR Q SERIES MODULE (NO NEED POWER SUPPLY) |
| Q55B | 5 I/O SLOTS, FOR Q SERIES MODULE (NO NEED POWER SUPPLY) |
| POWER SUPPLY | |
| Q61P-A1 | 100-120V AC INPUT/5VDC 6A OUTPUT, CE/UL/Cul |
| Q61P-A2 | 200-240V AC INPUT/5VDC 6A OUTPUT, CE/UL/cUL |
| Q62P | 100-240V AC INPUT/5VDC 3A, 24VDC/0.6A OUTPUT |
| Q63P | 24VDC INPUT/5VDC 6A OUTPUT |
| Q64P | 100-120/200-240V AC INPUT/5VDC 8.5A OUTPUT |
| EXTENSION CABLE | |
| QC05B | 0.45m (1.48ft.) |
| QC06B | 0.6m (1.96ft.) |
| QC12B | 1.2m (3.93ft.) |
| QC30B | 3m (9.84ft.) |
| QC50B | 5m (16.4ft.) |
| QC100B | 10m (32.8ft.) |
| BATTERY | |
| Q6BAT | REPLACEMENT BATTERY FOR MEMORY BACKUP |
| ADAPTOR | |
| Q6DIN1 | DIN RAIL MOUNTING ADAPTER, FOR Q38B/Q312B/Q68B/Q612B |
| Q6DIN2 | DIN RAIL MOUNTING ADAPTER, FOR Q35B/Q65B |
| Q6DIN3 | DIN RAIL MOUNTING ADAPTER, FOR Q33B/Q63B |
| MEMORY CASSETTE | |
| Q2MEM-1MBS | SRAM MEMORY CARD CAPACITY: 1M BYTES |
| Q2MEM-2MBS | SRAM MEMORY CARD CAPACITY: 2M BYTES |
| Q2MEM-2MBF | LINEAR FLASH MEMORY CARD CAPACITY: 2M BYTES |
| Q2MEM-4MBF | LINEAR FLASH MEMORY CARD CAPACITY: 4M BYTES |
| Q2MEM-8MBA ATA | ATA CARD CAPACITY: 8M BYTES |
| Q2M2M-16MBA ATA | ATA CARD CAPACITY: 16M BYTES |
| Q2MEM-32MBA ATA | ATA CARD CAPACITY: 32M BYTES |
| SRAM CARD BATTERY | |
| Q2MEM-BAT | REPLACEMENT BATTERY , FOR Q2MEM-1MBS |
| SOFTWARE | |
| GX-DEVELOPER-E | PROGRAM SOFTWARE, WINDOW VERSION (GPPW/LLT) - ENG. |
| GX-DEVELOPER-C | PROGRAM SOFTWARE, WINDOW VERSION (GPPW/LLT) - CHIN. |
| GX-CONFIG | AD MODULE SETTING TOOL FOR Q PLC - ENG |
| GX-CONFIG. | DA DA MODULE SETTING TOOL FOR Q PLC - ENG |
| GX-CONFIG. | CT HIGH SP. PROCESSING MODULE SETTING TOOL FOR Q-PLC - ENG. |
| GX-CONFIG. | TC TEMP. CONTROL MODULE SETTING TOOL FOR Q-PLC - ENG. |
| GX-CONFIG. | L-NET MODULE SETTING TOOL FOR Q-PLC - ENG |
| GX-CONFIG. | PT QD70P POSITION MODULE SETTING TOOL FOR Q-PLC - ENG. |
| GX-CONFIG. | QD75P/D/M POSITION MODULE SETTING TOOL FOR Q-PLC - ENG. |
| GX-CONFIG | SERIAL COMMUNICATION MODULE SETTING TOOL - ENG. |
| MX COMPONENT | ACTIVE X LIBRARY FOR COMMUNICA TION - ENG. |
| MX LINK - E | DDL LIBRARY FOR COMMUNICATION (ENG.) |
| INPUT UNIT | |
| QX10 | QX10 100-120V AC/7-8mA, 16pt |
| QX28 | QX28 240V AC, 8pt |
| QX40 | QX40 240V AC/4mA, POSITIVE COMMON INPUT, 16pt |
| QX40-S1 | 24VDC, POSITIVE COMMON INPUT, 16pt (HIGH SPEED) |
| QX41 | 24VDC, POSITIVE COMMON INPUT, 32pt |
| QX41-S1 | 24VDC, POSITIVE COMMON HIGH-SPEED INPUT, 32pt |
| QX42 | 24VDC, POSITIVE COMMON INPUT, 64pt |
| QX42-S1 | 24VDC, POSITIVE COMMON HIGH-SPEED INPUT, 64pt |
| QX70 | INPUT, POSITIVE AND NEGATIVE COMMON INPUT, 16pt |
| QX71 | INPUT, POSITIVE AND NEGATIVE COMMON INPUT, 32pt |
| QX72 | 12VDC INPUT, POSITIVE AND NEGATIVE COMMON INPUT, 64pt |
| QX80 | 4VDC/4mA. NEGATIVE COMMON INPUT, 16pt, TERMINAL BLOCK |
| QX81 | 24VDC/4mA. NEGATIVE COMMON INPUT, 16pt, CONNECTOR |
| OUTPUT UNIT | |
| QY10 | 240V AC/24VAC, 16pt, WITHOUT FUSE |
| QY18A | 240VAC/24V AC, 2A, 8 INDEPENDENT OUTPUT |
| QY22 | 240V AC/0.6A, 16pt, WITHOUT FUSE |
| QY40P | 12/24VDC, 16pt, WITH SHORT-CIRCUIT PROTECTION |
| QY41P | 12/24VDC, 32pt, WITH SHORT-CIRCUIT PROTECTION |
| QY42P | 12/24VDC, 64pt, WITH SHORT-CIRCUIT PROTECTION |
| QY50 | 12/24VDC, 16pt, WITH FUSE |
| QY68A | 5-24VDC, 8pt, WITHOUT FUSE |
| QY70 | 5/12VDC, 16pt, WITHOUT FUSE |
| QY71 | 5/12VDC, 32pt, WITHOUT FUSE |
| QY80 | 12/24VDC, 16pt, WITHOUT FUSE |
| QY81P | 12/24VDC, 32pt, WITH SHORT-CIRCUIT PROTECTION |
| I/O COMPOSITE UNIT | |
| QH42P | 24VDC POSITIVE COMMON INPUT, 32pt, OUTPUT: 32pt |
| QX48Y57 | 24VDC POSITIVE COMMON INPUT, 8pt, OUTPUT: 7pt |
| I/O CONNECTOR | |
| A6CON1 | SOLDERING 32-pt CONNECTOR |
| A6CON2 | CRIMP-CONTACT CONNECTION 32-pt CONNECTOR |
| A6CON3 | FLAT CABLE PRESSURE-DISPLACEMENT 32-pt CONNECTOR |
| A6CON1E | SOLDERING 32-pt CONNECTOR |
| A6CON2E | CRIMP-CONTACT CONNECTION 32-pt CONNECTOR |
| A6CON3E | FLAT CABLE PRESSURE-DISPLACEMENT 32-pt CONNECTOR |
| INTERRUPT UNIT | |
| QI60 | 16pt, RESPONSE TIME: 0FF-ON 0.2ms, ON-OFF 0.3ms OR SMALLER |
| ANALOG UNIT | ANALOG UNIT |
| Q64AD | 4 CHANNELS, A/D CONVERSION: VOLTAGE/CURRENT INPUT |
| Q68ADV | 8 CHANNELS, A/D CONVERSION: VOLTAGE INPUT |
| Q68ADI | 8 CHANNELS, A/D CONVERSION: CURRENT INPUT |
| Q62DA | 2 CHANNELS, D/A CONVERSION: VOLTAGE/CURRENT OUTPUT |
| Q64DA | 4 CHANNELS, D/A CONVERSION: VOLTAGE/CURRENT OUTPUT |
| Q68DA | V 8 CHANNELS, D/A CONVERSION: VOLTAGE OUTPUT |
| Q68DAI | 8 CHANNELS, D/A CONVERSION: CURRENT OUTPUT |
| CHANNEL-ISOLATED ANALOG UNIT | |
| Q64AD-GH | 4 CHANNELS, A/D CONVERSION: VOLTAGE/CURRENT INPIT |
| Q62AD-DGH | 2 CHANNELS, A/D CONVERSION, SIGNAL CONDITIONING FUNCTION |
| Q62DA-FG | 2 CHANNELS, D/A CONVERSION: V/I OUTPUT WITH MONITOR |
| TEMPERATURE INPUT/CONTROL UNIT | |
| Q64RD | 4 CHANNELS, PLATINUM RESIST. THERMO. INPUT |
| Q64TCTT | THERMO-COUPLE INPUT - TRANS. OUTPUT |
| Q64TCTTBW | THERMO-COUPLE INPUT WITH SHORT CIRCUIT DETECTION |
| Q64TCRT | PLATINUM RESIST. THERMO. INPUT |
| Q64TCRTBW | PLAT. RESIST. THERMO. INPUT WITH SHORT CIRCUIT DETECTION |
| CHANNEL-ISOLATED THERMOCOUPLE INPUT UNIT | |
| Q64TD | 4 CHANNELS, THERMO-COUPLE INPUT |
| Q64TDV-GH | 4 CHANNELS, THERMO-COUPLE INPUT, MICRO VOLTAGE INPUT |
| HIGH SPEED COUNTER UNIT | |
| QD62 | 2 CHANNELS, 200kpps, 5/12/24VDC INPUT, SINK TRANS. OUTPUT |
| QD62D | 2 CHANNELS, 500kpps, DIFFERENTIAL INPUT, SINK TRANS. OUTPUT |
| QD62E | 2 CHANNELS, 200kpps, 5/12/24VDC INPUT, SOURCE TRANS. OUTPUT |
| CHANNEL-ISOLATED PULSE INPUT UNIT | |
| QD60P8-G | 8 CHANNELS, 5/12 TO 24VDC INPUT, INPUT FILTER SETTING |
| POSITIONING UNIT | |
| QD75P1 | 1 AXIS, OPEN COLLECTOR OUTPUT |
| QD75P2 | 2 AXIS, OPEN COLLECTOR OUTPUT |
| QD75P4 | 4 AXIS, OPEN COLLECTOR OUTPUT |
| QD75D1 | 1 AXIS, DIFFERENTIAL OUTPUT |
| QD75D2 | 2 AXIS, DIFFERENTIAL OUTPUT |
| QD75D4 | 4 AXIS, DIFFERENTIAL OUTPUT |
| QD75M1 | 1 AXIS SSCNET COMPATIBLE |
| QD75M2 | 2 AXIS SSCNET COMPATIBLE |
| QD75M4 | 4 AXIS SSCNET COMPATIBLE |
| QD70P4 | 4 AXIS PULSE OUTPUT |
| QD70P8 | 8 AXIS PULSE OUTPUT |
| BLANK COVER | |
| QG60 | BLANK COPVER FOR I/O SLOT |
| CONNECTION CABLE | |
| QC30R2 | RS-232 CABLE FOR THE CONNECTION BETWEEN PC AND PLC CPU |
| TERMINAL BLOCK ADAPTOR | |
| Q6TA32 | FOR 32-POINT I/O, 0.5MM |
| (AWG20) 620 | (AWG20) 620 |
| TERMINAL BLOCK ADAPTOR-DEDICATED TOOL | |
| Q6TA32-TOL | TOOL EXCLUSIVELY USED FOR Q6TA32 |
| NEYWORK AND COMMUNICATION UNIT | |
| QJ71E71-B2 | ETHERNET UNIT FOR 10BASE-2 |
| QJ71E71-B5 | ETHERNET UNIT FOR 10BASE-5 |
| QJ71E71-100 | ETHERNET UNIT FOR 10BASE-T/10BASE-TX |
| QJ71LP21-25 | MELSECNET/10H UNIT FOR SI/QSI OPTICAL CABLE, DUPLEX LOOP |
| QJ71LP21G | MELSECNET/10H UNIT FOR 50GI OPTICAL CABLE, DUPLEX LOOP |
| QJ71LP21GE | MELSECNET/10H UNIT FOR 62.5GI OPTICAL CABLE, DUPLEX LOOP |
| QJ72LP25-25 | MELSECNET/10H UNIT FOR DISTANCE SI/QSI OPTICAL CABLE |
| QJ72LP25G | MELSECNET/10H UNIT FOR DISTANCE 50GI OPTICAL CABLE |
| QJ72LP25GE | MELSECNET/10H UNIT FOR DISTANCE 62.5GI OPTICAL CABLE |
| QJ71BR11 | MELSECNET/10H UNIT FOR COAXIAL 75 CABLE, SIMPLEX LOOP |
| QJ72BR15 | MELSECNET/10H UNIT FOR DISTANCE COAXIAL 75 CABLE |
| Q80BD-J71LP21-25 | MELSECNET/10H UNIT FOR OPTICAL CABLE |
| Q80BD-J71LP21G | MELSECNET/10H UNIT FOR SI/QSI/H-PC OPTICAL CABLE |
| Q80BD-J71BR11 | MELSECNET/10H UNIT FOR COAXIAL CABLE |
| QJ61BT11 | CC-LINK UNIT FOR MASTER/LOCAL |
| QJ71C24 | SERIAL COMMUNICATION UNIT FOR RS232C 1ch, RS422/485 1ch |
| QJ71C24-R2 | SERIAL COMMUNICATION UNIT FOR RS232C 2ch |
| QJ71CMO | RS-232 1ch |
| QD51 | INTELLIGENT COMMUNICATION UNIT FOR RS232 2ch |
| QD51-R24 | INTELLIGENT COMMUNICATION UNIT FOR RS-232 1ch, RS422/485 1ch |
| SW1IVD-AD51HP | QD51 SOFTWARE PACKAGE |
| QJ71FL71 | FL-NETWORK UNIT FOR 10BASE-5/10BASE-T |
| QJ71FL71-B2 | FL-NETWORK UNIT FOR 10BASE-2 |
| EXTENSION BASE MODULE | |
| QA1S65B | QA1S65B POWER SUPPLY +5 -I/O SLOTS, FOR AnS SERIES MODULE LOADING 1,440 |
| QA1S68B | QA1S68B POWER SUPPLY +8 -I/O SLOTS, FOR AnS SERIES MODULE LOADING 2,060 |
| QA65B | QA65B POWER SUPPLY +5 -I/O SLOTS, FOR A SERIES MODULE LOADING 3,560 |
| CPU - A MODE | |
| Q02CPU-A | PROGRAM CAPACITY: 28K STEPS |
| Q02HCPU-A | PROGRAM CAPACITY: 28K STEPS (HIGH SPEED) |
| Q06HCPU-A | PROGRAM CAPACITY: 60K STEPS (HIGH SPEED) |
| BATTERY | |
| Q6BAT | REPLACEMENT BATTERY FOR Q02/Q02H/Q06HCPU |
| MEMORY CASSETTE | |
| Q2MEM-1MBS | SRAM MEMORY CARD, CAPACITY: 1M BYTES |
| BASE UNIT, EXTENSION UNITS | |
| QA1S33B | POWER SUPPLY + CPU + 3 I/O SLOTS FOR AnS MODULE LOADING |
| QA1S35B | POWER SUPPLY + CPU + 5 I/O SLOTS FOR AnS MODULE LOADING |
| QA1S38B | POWER SUPPLY + CPU + 8 I/O SLOTS FOR AnS MODULE LOADING |
| QA1S65B | POWER SUPPLY + 5 I/O SLOTS FOR AnS MODULE LOADING |
| QA1S68B | POWER SUPPLY + 8 I/O SLOTS FOR AnS MODULE LOADING |
| EXTENSION CABLE | |
| QC06B | 0.6m (1.97ft.) |
| QC12B | 1.2m (3.93ft.) |
| QC30B | 3m (9.84ft.) |
| QC50B | 5m (16.39ft.) |
| QC100B | 10m (32.79ft.) |